Attention:
The default service IP addresses on your new Storwize V7000 Unified
control enclosure might conflict with existing devices that are attached to the
network or with other new control enclosures that you are installing. The service
IP address 192.168.70.121 subnet mask 255.255.255.0 is preconfigured on Ethernet
port 1 of the upper canister, canister 1. The service IP address 192.168.70.122 subnet
mask 255.255.255.0 is preconfigured on Ethernet port 1 of the lower canister,
canister 2.
If you encounter that situation, change the service IP addresses on the new nodes
before connecting the Ethernet cables. For details, see Figure 54 on page 93 or see
the
Storwize V7000 Unified Problem Determination Guide
PDF on the DVD for further
information about setting service IP addresses using a USB flash drive.
Follow these steps:
1.
For each node canister in the control enclosure, connect an Ethernet cable
between Ethernet port 1 of the canister and the Ethernet network.
Note:
Ethernet cables are not supplied as part of your order. A CAT 5
unshielded twisted pair (UTP) is the minimum requirement for an Ethernet
cable.
Ensure that cables are installed in a tidy manner to reduce the risk of cable
damage.
2.
Optionally attach Ethernet cables between Ethernet port 2 on each node
canister and your Ethernet network.
File module to file module:
v
Connect an Ethernet cable from Ethernet port 1 on the first file module to the
first Ethernet port on the second file module. Refer to Figure 54 on page 93 for
port locations.
Note:
Ethernet cables for the internal network are provided by IBM with the file
modules.
v
Connect an Ethernet cable from Ethernet port 2 on first file module to Ethernet
port 2 on the second file module.
v
Route the Ethernet cables through the cable management arms, and secure any
excess using the cable retention features of the rack.
File module management ports:
v
Connect an Ethernet cable from Ethernet port 3 on the first file module to an
Ethernet network. If using two Ethernet cables (as recommended), connect
another Ethernet network cable to Ethernet port 4. When using only one
Ethernet port, the network status is marked as degraded and an associated
warning event is listed in the health center.
v
Repeat the previous step for the second file module.
v
Route the Ethernet cables through the cable management arm, and secure any
excess using the cable retention features of the rack.
File modules to external (host ports) network (10 GB Fibre Ethernet):
You have two 10 Gbps Fibre Ethernet ports available for host connections from
each file module. The ports are on the PCI card located in slot 4. Connect your
network cables to the Ethernet ports in these slots as applicable. Refer to Figure 54
on page 93.
94
IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720
Summary of Contents for Storwize V7000