The information in Table 5 on page 14 is required before initializing your system.
Fill in all the information needed in the
Value
column before starting the initial
setup of your system using the Initialization tool (InitTool.exe).
You should also fill in all of the information needed in “Information required
before starting initial configuration of your system” on page 15 before you start
initializing your system.
WARNING:
You must check carefully that the IP addresses that you provide to
InitTool.exe are valid and not already in use by some other system on the network
apart from the gateway IP address. Refer to “Checking that IP addresses are not
already in use” on page 12. If you provide an IP address that is already in use then
the initial setup may appear to be successful and the system could work for some
time before random problems start to happen which are very hard to troubleshoot.
If you need to change an IP address after initial setup has completed then refer to
Connectivity issues for the 2073-720, located in the Troubleshooting topic of the
Information Center,for examples of changing IP addresses.
123.123.123.102
123.123.123.104
123.123.123.103
123.123.123.11
123.123.123.101
123.123.123.12
99.99.99.100
99.99.99.101
123.123.123.21
123.123.123.22
99.99.99.200
99.99.99.1
A
B
C
E
1
F
2
D
3
123.123.123.10
ifs00053
G
File Module 1
File Module 2
Node canister 1
Node canister 2
Control Enclosure
AA
BB
CC
DD
EE
V7000 Unified
H
123.123.123.20
Legend for above graphic:
v
1
File storage path
v
2
Block storage path
v
3
Remote support services via internet
v
A
DNS server
v
B
NTP server
v
C
Email server
v
D
Authentication server
Chapter 1. Before you begin the installation
13
Summary of Contents for Storwize V7000
Page 1: ...IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide GC27 5945 01...
Page 20: ...xx IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...
Page 48: ...28 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...
Page 82: ...62 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...
Page 92: ...72 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...
Page 100: ...80 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...
Page 101: ......
Page 102: ...Part Number 00AR284 Printed in USA GC27 5945 01 1P P N 00AR284...