Force-online operation
Sometimes the logical drives might go to an Offline state even if all the hard drives
are working correctly. In such cases, if you know that the data on that logical array
is in a working state, you can force the array to an Online or Critical state
(depending upon the earlier state of the array). This feature helps recover the data
by forcing the logical drive from Offline to Online or Critical state. Use the
force-online option only as a last attempt to recover data. Do not use such an array
for production purposes.
You can force an Offline array to Online / Critical Revived by using the BIOS,
ServeRAID Manager (SRM) GUI, or the Adaptec RAID Controller Configuration
(ARCCONF) Force-Online operation option.
BIOS
To force an Offline array to Online / Critical Revived by using the BIOS, complete
the following steps:
1. Select
Manage Containers
in the Array configuration utility.
2. Use the Up and Down keys to navigate to an Offline array.
3. Press Ctrl+R to perform a force online operation on that logical array.
4. Press Y to continue the force online operation.
The
Success in Force On-Line Process
message is displayed after the array is
created.
The
Failure in Force On-Line Process
message is displayed if the array is not
created.
36
ServeRAID-8 Series: Best Practices and Maintenance Information
Summary of Contents for ServeRAID-8 Series
Page 1: ...ServeRAID 8 Series Best Practices and Maintenance Information...
Page 2: ......
Page 3: ...ServeRAID 8 Series Best Practices and Maintenance Information...
Page 6: ...Index 49 iv ServeRAID 8 Series Best Practices and Maintenance Information...
Page 41: ...Chapter 1 ServeRAID 8 series best practices and maintenance information 35...
Page 54: ...48 ServeRAID 8 Series Best Practices and Maintenance Information...
Page 57: ......
Page 58: ...Part Number 46M1375 Printed in USA 1P P N 46M1375...