Table 4. Logical drive state descriptions (continued)
Logical drive state
Description
Offline
The logical drive is in an Offline state and is not
accessible. This state occurs when one of the following
scenarios is true:
v
One or more physical drives in a RAID level-0 logical
drive are defunct.
v
Two or more physical drives in a RAID level-1,
level-1E, or level-5 logical drive are defunct.
v
Three or more drives in a RAID level-5EE logical drive
or RAID level-6 logical drive are defunct.
v
One or more drives in a RAID level-5EE logical drive
fail while a compaction is in progress. If the drive fails
after the RAID level-5EE logical drive is in a
Compacted state, the array becomes Critical.
Note:
For more information if any of the preceding
scenarios is true, see the section “Rebuilding a Defunct
Drive” in the
IBM ServeRAID User's Reference
on the
IBM
ServeRAID Support CD
.
Okay
The logical drive is working correctly. It is in a good,
functional state.
Okay Revived
The logical drive has recovered to a Okay Revived state.
This state occurs when a logical drive is brought from an
Offline state to an Okay state by using a force online
operation. If no drives are removed, the logical drive
remains in an Okay Revived state until the array is
deleted.
Offline Revived
The logical drive changes state from an Okay Revived,
Critical (revived), or Degraded (revived) state to an Offline
Revived state because of one or more drive failures.
Degraded (revived)
The logical drive has recovered to a Degraded (revived)
state in RAID 6, based on the following scenarios:
v
When a force online operation is performed on an
Offline state logical drive that has one defunct physical
drive in its configuration.
v
One of the physical disks is marked defunct from an
Okay (revived) state configuration.
Chapter 1. ServeRAID-8 series best practices and maintenance information
31
Summary of Contents for ServeRAID-8 Series
Page 1: ...ServeRAID 8 Series Best Practices and Maintenance Information...
Page 2: ......
Page 3: ...ServeRAID 8 Series Best Practices and Maintenance Information...
Page 6: ...Index 49 iv ServeRAID 8 Series Best Practices and Maintenance Information...
Page 41: ...Chapter 1 ServeRAID 8 series best practices and maintenance information 35...
Page 54: ...48 ServeRAID 8 Series Best Practices and Maintenance Information...
Page 57: ......
Page 58: ...Part Number 46M1375 Printed in USA 1P P N 46M1375...