Chapter 5. Technical Specifications
These are the technical specifications for installing and using the SAN48C-6 switch.
Switch Specifications
The following table lists the environmental specifications for the IBM SAN48C-6 switch:
Table 3. Environmental Specifications for the IBM SAN48C-6SAN48C-6 Switch
Description
Specification
Temperature, ambient operating
32 to 104°F (0 to 40°C)
Temperature, ambient nonoperating and storage
-40 to 158°F (-40 to 70°C)
Humidity (RH), ambient (noncondensing) operating
10 to 90%
Humidity (RH), ambient (noncondensing)
nonoperating and storage
10 to 95%
Altitude, operating
-197 to 6500 ft (-60 to 2000 m)
The following table lists the physical specifications for the IBM SAN48C-6SAN48C-6 switch.
Table 4. Physical Specifications for the IBM SAN48C-6SAN48C-6 Switch
Description
Specification
Dimensions (HxWxD)
1.72 x 17.3 x 22.3 in. (4.37 x 43.94 x 56.64 cm)
excluding PSU and fan module handles
Rack Space
Chassis requires 1 RU (1.75 in. or 4.45 cm)
Weight
18.73 lb (8.5 kg)
Fan Dimensions (WxH)
1.575 x 1.575 in. (4.0 x 4.0 cm)
Fan Slots Opening Dimensions (WxH)
1.614 x 1.602 in. (4.09 x 4.06 cm)
Power Supply
• 650-W AC, port-side exhaust variant (up to 2 per
switch)
• 650-W AC, port-side intake variant (up to 2 per
switch)
• AC input—100 to 240 V AC (10% range)
• Frequency—50 to 60 Hz (nominal)
©
Copyright IBM Corp. 2021
37