Domain: (1..239) [1] 3
e) Complete the remaining prompts or press
Ctrl+D
to accept the remaining settings without
completing all the prompts.
f) Re-enable the switch by entering the
switchEnable
command.
Verifying correct operation
Perform the following steps to verify correct operation of the device.
1. Check the LEDs to verify that all components are functional.
2. Verify the correct operation of the device by entering the following commands from the workstation.
Command
Description
psShow
Displays power supply status and information
fanShow
Displays fans status and information
switchShow
Displays switch status and information
tempShow
Displays temperature status and information
historyShow
Displays the device history
errDump
Displays any errors
The
switchShow
command provides the following information about the device and ports status.
G730switch:FID128:admin> switchshow switchName: ras030
switchType: 189.3
switchState: Online switchMode: Native switchRole: Subordinate switchDomain: 30
switchId: fffc1e
switchWwn: 10:00:c4:f5:7c:02:31:98 zoning: ON (WB_RAS159_64G_LSAN)
switchBeacon: OFF
FC Router: OFF
Fabric Name: Serviceability_Testbed HIF Mode: OFF
Allow XISL Use: OFF
LS Attributes: [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: No, Address
Mode 0]
Index Port Address Media Speed State Proto
==================================================
0 0 1e0000 -- N64 No_Module FC (Ports on Demand license not assigned or
reserved
yet) (output truncated)
94 94 1e5e00 -- N64 No_Module FC (Ports on Demand license not assigned or
reserved
yet)
95 95 1e5f00 -- N64 No_Module FC (Ports on Demand license not assigned or
reserved
yet)
96 96 1e6000 id N64 Online FC E-Port (Trunk port, master is Port 97 )
97 97 1e6100 id N64 Online FC E-Port 10:00:d8:1f:cc:03:3e:a0 "ras232"
(Trunk
master)
98 98 1e6200 -- N64 No_Module FC (Ports on Demand license not assigned or
reserved
yet)
99 99 1e6300 -- N64 No_Module FC (Ports on Demand license not assigned or
reserved
yet)
(output truncated)
The tempshow command shows the current temperature of the EM sensors.
switch:admin> tempshow
Sensor ID|Sensor Index|State |Centigrade |Fahrenheit |
1 |0 |Ok |30 |86 |
2 |1 |Ok |34 |93 |
3 |2 |Ok |29 |84 |
Chapter 4. Initial Setup and Verification 39