background image

b. Disable any additional adapters other than the Local Area Connection.

c. Right click the adapter and select Properties.

d. Click Internet Protocol Version 4 (TCP/IPv4) and select Properties.

Note: If you are returning the device to the network after you set up the Operations Console, record

the IP information that is displayed.

e. Select Obtain an IP address automatically. This ensures that the PC receives an IP address in the

169.254.x.x range.

4. To disable the PC firewall, complete the following steps.

Note: All PC firewalls must be disabled for the initial connection.

a. In the Windows control panel, click Firewall settings and disable the firewall.
b. In the Windows control panel, click Security center. Check for a firewall and, if present, disable it.

c. Scan all tasks that are running on the PC for any other software firewalls and disable the firewall.

5. Power on the server by completing the following steps:

a. Set the manual initial program load (IPL) by completing the following steps:

i) Locate the server's control panel.

ii) Press the Up arrow key until you see 02, and press Enter.

iii) Press Enter again. A < (less than symbol) appears next to N.
iv) Press the Up Arrow key. The N changes to an M.

v) Press Enter.

vi) Press Enter twice. A 02 is displayed on the control panel.

b. After you have the server set to a manual IPL, push the white power button to power on the server.

Note: During the IPL, the system displays C6004031 on the control panel, which indicates that the

system is searching for an Operations Console. The system might take 20 - 30 minutes to complete

this action. If A6005008 is displayed on the control panel, this means that no Operations Console

is available. This might indicate that the system is not preinstalled with IBM i and you must set the

console type to LAN.

6. Perform this step if the system is not preinstalled with IBM i. For setting the console type to LAN,

complete the following steps:

a. Enable the control panel functions by completing the following steps:

i) Select function 25 on the control panel and press Enter. The return code must be 00.

ii) Select function 26 on the control panel and press Enter.

Note: If you see a FF return code, go back to function 25 and press Enter, then return to function

26 and press Enter.

b. Check your current setting(s). Use console service functions (65+21+11) to check the current

setting.
• A600 500A = No console defined
• A603 500A = LAN console
• A604 500A = HMC console
If the system reference code (SRC) = A603500A, skip to step “7” on page 8. For all others SRCs,

continue with the next step.

c. Set console type to LAN.

For release 7.4 and earlier, complete the following steps.

i) Use the 65+21+11 sequences until it returns A603500B. This indicates that the console type

will be changed to LAN.

Installing the IBM Power S1014 (9105-41B)  7

Summary of Contents for Power S1014

Page 1: ...Power Systems Installing the IBM Power S1014 9105 41B IBM GI11 0002 00...

Page 2: ...1110 and G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER10 processor and to all associated models Copyrig...

Page 3: ...server to the installation site 1 Completing inventory for your stand alone server 1 Cabling the server and setting up a console 2 Completing the server setup 9 Notices 13 Accessibility features for...

Page 4: ...iv...

Page 5: ...erordnung geeignet Laser safety information IBM servers can use I O cards or features that are fiber optic based and that utilize lasers or LEDs Laser compliance IBM servers may be installed inside or...

Page 6: ...power attach the power cords to the outlets 5 For racks with a DC power distribution panel PDP restore the power from the Customer s DC power source and turn on the circuit breakers located in the PDP...

Page 7: ...g or overcurrent protection To provide the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply cir...

Page 8: ...ned at more than 10 degrees When the rack cabinet is in the new location complete the following steps Lower the four leveling pads Install stabilizer brackets on the rack cabinet or in an earthquake e...

Page 9: ...sition read the installation instructions Do not put any load on the slide rail mounted equipment mounted in the installation position Do not leave the slide rail mounted equipment in the installation...

Page 10: ...power cords and power cables L003 L007 CAUTION A hot surface nearby L007 L008 CAUTION Hazardous moving parts nearby L008 L018 or CAUTION High levels of acoustical noise are or could be under certain c...

Page 11: ...exposure C026 CAUTION Data processing environments can contain equipment transmitting on system links with laser modules that operate at greater than Class 1 power levels For this reason never look i...

Page 12: ...tended platform Only raise load if properly centered on platform Do not place more than 200 lb 91 kg on edge of sliding platform shelf also considering the load s center of mass gravity CoG Do not cor...

Page 13: ...ing System GR 1089 CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS Network Equipment Building System GR 1089 CORE The equipment is suitable for ins...

Page 14: ...xiv Power Systems Installing the IBM Power S1014 9105 41B...

Page 15: ...ates and fixes see the Hardware Management Console Support and downloads website https www14 software ibm com webapp set2 sas f hmcl home html Consider the following prerequisites before you install t...

Page 16: ...ntenance and control The eBMC also provides access to the system event log files SEL The eBMC is a specialized service processor that monitors the physical state of the system by using sensors A syste...

Page 17: ...page 6 Keyboard video and mouse KVM Linux or VIOS Yes Monitor and USB cables equipped with KVM Cabling the server with keyboard video and mouse on page 5 Cabling the server with an ASCII terminal If...

Page 18: ...e power supplies are flashing If none of the indicators are flashing check the power cord connections 3 Wait for the green light on the control panel to start flashing 4 Ensure that your ASCII termina...

Page 19: ...com support knowledgecenter POWER9 p10hai p10hai_netconhmc htm Notes You can also have multiple systems that are attached to a switch that is then connected to the HMC For instructions see HMC networ...

Page 20: ...M i Access ACS Getting Started https www ibm com support pages ibm i access acs getting started 3 0 Note It is recommended that you log onto the PC as the local administrator This ensures that you hav...

Page 21: ...e server set to a manual IPL push the white power button to power on the server Note During the IPL the system displays C6004031 on the control panel which indicates that the system is searching for a...

Page 22: ...the information to be displayed 8 To set a static IP address for the Operations Console complete the following steps a Sign on with QSECOFR The default password is QSECOFR and it is case sensitive b A...

Page 23: ...the following steps i Connect the system power cords from the server and I O drawers to the PDU with an IEC 320 type receptacle ii Attach the PDU input power cord and plug it into the power source ii...

Page 24: ...date the time of day on the managed system by using the Advanced System Management Interface ASMI To access ASMI by using the HMC complete the following steps a In the contents area select the managed...

Page 25: ...edgecenter POWER10 p10hdx p10hdx_installlinux htm Install the VIOS operating system For instructions see Installing VIOS https www ibm com support knowledgecenter POWER10 p10hb1 p10hb1_vios_install ht...

Page 26: ...the operating system Install the AIX operating system For instructions see Installing AIX http www ibm com support knowledgecenter POWER10 p10hdx p10hdx_installaix htm Install the Linux operating sys...

Page 27: ...oduct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner...

Page 28: ...st users who have a disability such as restricted mobility or limited vision to use information technology content successfully Overview The IBM Power servers include the following major accessibility...

Page 29: ...deployed for this Software Offering provide you as the customer the ability to collect personally identifiable information from end users via cookies and other technologies you should seek your own le...

Page 30: ...nforderungen der EU Richtlinie 2014 30 EU zur Angleichung der Rechtsvorschriften ber die elektromagnetische Vertr glichkeit in den EU Mitgliedsstaatenund h lt die Grenzwerte der EN 55022 EN 55032 Klas...

Page 31: ...ormationen Das Ger t erf llt die Schutzanforderungen nach EN 55024 und EN 55022 EN 55032 Klasse A Japan Electronics and Information Technology Industries Association JEITA Notice This statement applie...

Page 32: ...ssion FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable pr...

Page 33: ...to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts Class B Notices The following Class B statements apply to features designated as electro...

Page 34: ...ormit tszeichen CE zu f hren Verantwortlich f r die Einhaltung der EMV Vorschriften ist der Hersteller International Business Machines Corp New Orchard Road Armonk New York 10504 Tel 914 499 1900 Der...

Page 35: ...by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differe...

Page 36: ...ay these publications or any portion thereof outside your enterprise without the express consent of IBM Rights Except as expressly granted in this permission no other permissions licenses or rights ar...

Page 37: ......

Page 38: ...IBM Part Number 03KG354 GI11 0002 00 1P P N 03KG354...

Reviews: