Replacing the Real-Time Clock
9. Reinstall the board-support panel:
a. Align the support panel so that the three tabs
.1/
at the
back left edge of the panel fit into the three chassis slots.
b. Close the panel. Check to make sure that the boards in the
slots behind the panel align with the scribe marks on the
panel. Use the scribe marks at
.2/
to check the alignment of
the memory board. Use the scribe marks at
.3/
to check the
alignment of the processor boards.
2
3
1
c. Secure the panel with the four screws that you removed in
step 1a on page 130.
10. Because your server contains a new RTC, you must reconfigure
your server to restore the system settings (for example, date and
time). To do this, run the System Configuration Utility program
as described in Chapter 2, “Configuring Your Server” on
page 29. Then, return here and continue with “What to do
next?” on page 134 to determine your next step.