15
Getting Started
F
EN
ES
C
Additional Information
Troubleshooting
This section may help you isolate the cause of a problem and as a result, eliminate the need to contact technical support.
Symptom
Check these items
No picture
If the
u
indicator is not lit
If the “NO INPUT SIGNAL”
message appears on the
screen, or if the
u
indicator is
either orange or alternating
between green and orange
If the “OUT OF SCAN
RANGE” message appears on
the screen
If no message is displayed
and the
u
indicator is green
or flashing orange
Picture is scrambled
Color is not uniform
You cannot adjust the
monitor with the buttons on
the front panel
Warning Messages
If there is something wrong with the input signal, one of the
following messages appears.
The input signal condition
“OUT OF SCAN RANGE”
indicates that the input signal
is not supported by the monitor’s specifications.
“NO INPUT SIGNAL”
indicates that no signal is input.
To solve these problems, see “Troubleshooting” below.
INFORMATION
OUT OF SCAN RANGE
Input signal condition
• Check that the power cord is properly connected.
• Check that the
u
(power) switch is in the “on” position.
• The screen is blank when the monitor is in power saving mode. Try pressing any key
on the computer keyboard.
• Check that your computer power switch is in the “on” position.
• Check that the video signal cable is properly connected and all plugs are firmly seated
in their sockets.
• Ensure that no pins are bent or pushed in the HD15 video input connector.
• Check that the video board is completely seated in the proper bus slot.
• Check that the video frequency range is within that specified for the monitor.
(Horizontal: 30 – 85 kHz, Vertical: 50 – 150 Hz)
Refer to your computer’s instruction manual to adjust the video frequency range.
• If you are using a video signal cable adapter, check that it is the correct one.
• See “Self-diagnosis Function” (page 17).
• Check your graphics board manual for the proper monitor setting.
• Check this manual and confirm that the graphics mode and the frequency you are
trying to operate at is supported. Even if the frequency is within the proper range,
some video boards may have a sync pulse that is too narrow for the monitor to sync
correctly.
• Degauss the monitor (page 10).
If you place equipment which generates a magnetic field, such as a loudspeaker, near
the monitor, or you change the direction of the monitor, color may lose uniformity.
The degauss function demagnetizes the metal frame of the CRT to obtain a neutral
field for uniform color reproduction. If a second degauss cycle is needed, allow a
minimum interval of 20 minutes for the best result.
• If the control lock function is set to on, set it to off using the OPTION OSD (page 11).