22
IBM® Netfinity® EXP300 Installation and User’s Guide
c. All hard disk drives are locked securely in place.
d. All switches are set correctly: the internal option switches 1 through 4,
external option switches 1 through 5, and the unit ID switch on the expansion
unit. See “Setting the interface options and ID settings” on page 11 for more
information.
2. Check the system documentation for all the hardware devices you intend to turn
on and determine the proper power-on sequence.
Note:
Be sure to turn on the IBM Netfinity EXP300 expansion unit before or at
the same time as you turn on the server.
3. Turn on each device, based on this power-on sequence.
4. Turn on both power supplies on the back of the unit.
The expansion unit might take a few seconds to turn on. During this time, you
might see the fault (amber) and the power (green) LEDs on the expansion unit
turn on and off intermittently. When the power-on sequence is complete, only the
power (green) LEDs on the front and back should remain on. If one or more fault
(amber) LEDs remain lit, refer to “Troubleshooting” on page 35.
Attention:
If you have data stored on the drives, label the drives before you
remove them. Then, when you replace the drives, install each one in the same
drive bay from which you removed it. Failure to do so will result in a loss of data.
Turning off the expansion unit
Attention:
Except in an emergency situation, never turn off the power if any fault
LEDs are lit on the expansion unit. Correct the fault before you attempt to turn off the
power, using the proper troubleshooting or servicing procedure. This will ensure that
the expansion unit will turn on correctly later. Refer to “Troubleshooting” on page 35.
The expansion unit is designed to run continuously, 24 hours a day. Turn off the
power only when at least one of the following is true:
•
Instructions in a hardware or software procedure require you to turn off the
power.
Statement 5
CAUTION:
The power control button on the device and the power supply do not turn off
the electrical current supplied to the device. The device also might have more
than one power cord. To remove all electrical current from the device, ensure
that all power cords are disconnected from the power source.
1
2
Summary of Contents for Netfinity EXP300
Page 1: ...IBM IBM Netfinity EXP300 Installation and User s Guide SC19 K842 30...
Page 2: ......
Page 3: ...IBM IBM Netfinity EXP300 Installation and User s Guide SC19 K842 30...
Page 6: ...iv IBM Netfinity EXP300 Installation and User s Guide...
Page 36: ...24 IBM Netfinity EXP300 Installation and User s Guide...
Page 46: ...34 IBM Netfinity EXP300 Installation and User s Guide...
Page 52: ...40 IBM Netfinity EXP300 Installation and User s Guide...
Page 68: ...56 IBM Netfinity EXP300 Installation and User s Guide...
Page 71: ......