IBM® Netfinity® 7600 Installation Guide
Troubleshooting chart
Power problems
Suggested action
The server does not power
on.
Verify that:
1. The power cables are properly connected to the server.
2. The electrical outlet functions properly.
3. The type of memory that is installed is correct.
4. If you just installed an option, remove it, and restart the server. If the
server now powers on, you might have installed more options than the
power supply can support.
5. The LEDs on the power supply are on.
If the problem remains, call for service.
Microprocessor problems
Suggested action
The server emits a
continuous tone during
POST.
The startup (boot) microprocessor is not working properly.
Verify that the startup microprocessor is seated properly. If it is, replace the
startup microprocessor.
If the problem remains, call for service.
Memory problems
Suggested action
The amount of memory
displayed is less than the
amount of memory installed.
Verify that:
1. The memory modules are seated properly.
2. You have installed the correct type of memory.
3. If you changed the memory, you updated the memory configuration
using the Configuration/Setup Utility program.
4. All banks of memory on the DIMMs are enabled. The server might
have detected a problem and automatically disabled a DIMM bank, or a
DIMM bank could have been manually disabled.
If the above items are correct, run the memory-diagnostic program. The
system might have detected a bad memory module and automatically
reallocated memory to enable you to continue to operate. If the memory
tests fail, call for service or replace the failing DIMM.
Summary of Contents for Netfinity 7100
Page 1: ...IBM IBM Netfinity 7600 Installation Guide SC09 N821 60 ...
Page 4: ...IBM Netfinity 7600 Installation Guide ...
Page 16: ...6 IBM Netfinity 7600 Installation Guide ...
Page 40: ...30 IBM Netfinity 7600 Installation Guide Troubleshooting chart ...
Page 56: ...46 IBM Netfinity 7600 Installation Guide ...
Page 58: ...48 IBM Netfinity 7600 Installation Guide ...
Page 59: ......