background image

This information is for planning purposes only. The information herein is subject to change before the
products described become available.

This information contains examples of data and reports used in daily business operations. To illustrate
them as completely as possible, the examples include the names of individuals, companies, brands, and
products. All of these names are fictitious and any similarity to the names and addresses used by an
actual business enterprise is entirely coincidental.

If you are viewing this information in softcopy, the photographs and color illustrations may not appear.

The drawings and specifications contained herein shall not be reproduced in whole or in part without the
written permission of the manufacturer.

The manufacturer has prepared this information for use with the specific machines indicated. The
manufacturer makes no representations that it is suitable for any other purpose.

The manufacturer's computer systems contain mechanisms designed to reduce the possibility of
undetected data corruption or loss. This risk, however, cannot be eliminated. Users who experience
unplanned outages, system failures, power fluctuations or outages, or component failures must verify the
accuracy of operations performed and data saved or transmitted by the system at or near the time of the
outage or failure. In addition, users must establish procedures to ensure that there is independent data
verification before relying on such data in sensitive or critical operations. Users should periodically check
the manufacturer's support websites for updated information and fixes applicable to the system and
related software.

Homologation statement

This product may not be certified in your country for connection by any means whatsoever to interfaces
of public telecommunications networks. Further certification may be required by law prior to making any
such connection. Contact an IBM representative or reseller for any questions.

Trademarks

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business
Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be
trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at
Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.

INFINIBAND, InfiniBand Trade Association, and the INFINIBAND design marks are trademarks and/or
service marks of the INFINIBAND Trade Association.

Electronic emission notices

When attaching a monitor to the equipment, you must use the designated monitor cable and any
interference suppression devices supplied with the monitor.

Class A Notices

The following electronic emission statements apply to this product. The statements for other products
that are intended for use with this product are included in their accompanying documentation.

Federal Communications Commission (FCC) statement

Note:

This equipment has been tested and found to comply with the limits for a Class A digital device,

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment

16

IBM FlashSystem: Installing the IBM FlashSystem 810

Summary of Contents for FlashSystem 810

Page 1: ...IBM FlashSystem Installing the IBM FlashSystem 810 GI11 9894 04...

Page 2: ......

Page 3: ...IBM FlashSystem Installing the IBM FlashSystem 810 GI11 9894 04...

Page 4: ...anual G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM FlashSystem and to all subsequent releases and modifications until otherwise indicated in new edi...

Page 5: ...nt panel display 7 Configuring a static IP address 8 Configuring DHCP 8 Connecting to the web management interface 9 Acquiring the system IP address 9 Accessing the web interface 9 Reformatting uninit...

Page 6: ...iv IBM FlashSystem Installing the IBM FlashSystem 810...

Page 7: ...ct The documentation contains the safety information in your national language with references to the U S English source Before using a U S English publication to install operate or service this produ...

Page 8: ...t that will be attached to this product to properly wired outlets v When possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire...

Page 9: ...e customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock CAUTION v Do not install a unit in a rack where the internal rack ambient temperatures will exceed t...

Page 10: ...an support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x...

Page 11: ...This product might contain one or more of the following devices CD ROM drive DVD ROM drive DVD RAM drive or laser module which are Class 1 laser products Note the following information v Do not remove...

Page 12: ...d cabling information for NEBS Network Equipment Building System GR 1089 CORE The following comments apply to the IBM servers that have been designated as conforming to NEBS Network Equipment Building...

Page 13: ...h a packing list Ensure that you received all of the components listed 1 Examine the external chassis for any damage that might have occurred during shipping 2 Inspect the interface plate for any scre...

Page 14: ...rrectly wired and grounded to prevent an electrical shock CAUTION v Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temp...

Page 15: ...A unit that corresponds to the EIA unit marked on the front of the rack 4 Mark the middle hole of the EIA unit 5 Mark the corresponding holes on the left side of the rack 6 Continue to the next sectio...

Page 16: ...system to a management network Your system includes a Gigabit Ethernet management controller port MCP connection for remote management over a network You use this connection to configure the system s...

Page 17: ...display shows the startup sequence When the system is fully ready the front panel displays Status OK and the system performance statistics including the system bandwidth and total input output operati...

Page 18: ...is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the...

Page 19: ...tatic IP DHCP or No Ethernet The default factory setting is DHCP For any questions that you have regarding IP assignment values consult your network administrator To set up the network by using the fr...

Page 20: ...hen press any key to dismiss this message Otherwise enter the gateway IP address 5 After you enter all the necessary values you can review them apply edit or cancel your changes through the Review Con...

Page 21: ...he lines below it 3 Take note of the IP address Accessing the web interface Learn to how to access the storage system web interface About this task To open the web interface complete the following ste...

Page 22: ...rollers Learn to use the web interface to configure the controllers Procedure 1 In the web interface system tree click the Interfaces node to view the Interfaces Overview pane A table of all Fibre Cha...

Page 23: ...Procedure 1 From the web interface select the Management node in the system tree 2 Select the Date Time node This action displays the current date and time and the length of time that the system has...

Page 24: ...Configuring the mail service The mail service function provides system event email notifications and the ability to email the system report directly for support purposes About this task To configure...

Page 25: ...Check for updates b To use the CLI enter the system status command at the command prompt 2 If a newer code level is available install it before going into production Firmware loads are not concurrent...

Page 26: ...the default password password or your system s unique username and password 3 At the command prompt enter diag to enter diagnostic mode 4 To confirm the command enter YES 5 From the diagnostic menu ty...

Page 27: ...or changes in the product s and or the program s described in this publication at any time without notice Any references in this information to websites not owned by the manufacturer are provided for...

Page 28: ...anufacturer s support websites for updated information and fixes applicable to the system and related software Homologation statement This product may not be certified in your country for connection b...

Page 29: ...formit la r glementation d Industrie Canada Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada European Community Compliance Statement This product is in conformity with the...

Page 30: ...Guideline with Modifications products greater than 20 A per phase Electromagnetic Interference EMI Statement People s Republic of China Declaration This is a Class A product In a domestic environment...

Page 31: ...Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt eingebaut werden EN 55022 Klasse A Ger te m ssen mit folgendem Warnhinweis versehen werden Warnung Dieses ist eine Einrich...

Page 32: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Page 33: ...of EU Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM cannot accept responsibility for any failure to satisfy the pro...

Page 34: ...n den Handb chern beschrieben zu installieren und zu betreiben Des Weiteren d rfen auch nur von der IBM empfohlene Kabel angeschlossen werden IBM bernimmt keine Verantwortung f r die Einhaltung der Sc...

Page 35: ...cial Use You may reproduce distribute and display these publications solely within your enterprise provided that all proprietary notices are preserved You may not make derivative works of these public...

Page 36: ...24 IBM FlashSystem Installing the IBM FlashSystem 810...

Page 37: ......

Page 38: ...Part Number 00DH781 Printed in USA GI11 9894 04 1P P N 00DH781...