• FSP interface (enP1p8s0f1)
b) Run the Assign IP to Interface option two times (EMS only) and change the target interface, that
is, f0 for management IP interface and f1 for the FSP interface.
Both IP addresses should be provided by the customer in the Installation worksheet as a part of
the TDA process. The HMC1 IP is also provided and set by using a different command.
2. Perform a ping test (from EMS node only).
Do a ping test from the EMS to the management interface of the first I/O server and then the
HMC1port. After the first data server ping test is complete, do the same ping test for the second data
server. Finally, perform the same ping tests to any protocol nodes (if applicable).
a) Highlight ping tests (do not click).
b) Press c to change the target IP address.
c) Change the target IP in the -N field.
The IP is the management IP that was set on the data server 1.
d) Press Ctrl+G keys to save.
e) Press Enter to run the command.
f) Change the target to the HMC1 IP address of the first data server.
g) Press Enter to run the command.
h) Repeat these steps for the data server 2.
If the ping is not successful, check the cabling and switch. You might need to log in as root to confirm
whether the IP address was set correctly. For more information, see IBM Elastic Storage System 5000:
Problem Determination Guide.
3. Press Enter to continue.
4. Do the following final steps:
a) Disconnect your laptop from EMS.
b) Ensure that no server or enclosure warning LEDs are on. If required, take the appropriate actions.
If all hardware is clean and IP addresses ping test is successful, Code 20 is completed.
40 IBM Elastic Storage System 5000: Hardware Guide
Summary of Contents for ESS 5000 SC Series
Page 1: ...IBM Elastic Storage System 5000 Version 6 0 1 Hardware Guide IBM SC28 3155 00 ...
Page 6: ...vi ...
Page 7: ...Tables 1 Conventions x vii ...
Page 8: ...viii ...
Page 12: ...xii IBM Elastic Storage System 5000 Hardware Guide ...
Page 60: ...48 IBM Elastic Storage System 5000 Hardware Guide ...
Page 62: ...50 IBM Elastic Storage System 5000 Hardware Guide ...
Page 64: ...52 IBM Elastic Storage System 5000 Hardware Guide ...
Page 72: ...60 IBM Elastic Storage System 5000 Hardware Guide ...
Page 74: ...62 IBM Elastic Storage System 5000 Hardware Guide ...
Page 76: ...64 IBM Elastic Storage System 5000 Hardware Guide ...
Page 77: ......
Page 78: ...IBM Product Number 5765 DME 5765 DAE SC28 3155 00 ...