5. Change the bootlist so the network adapter attached to the NIM server is first in the
bootlist.
6. Exit completely from SMS.
The system starts loading packets while doing a bootp from the network.
Follow the instructions on the screen to select the system console.
If
Diagnostics Operating Instructions Version x.x.x
is displayed, standalone
diagnostics have loaded successfully.
If the AIX login prompt is displayed, standalone diagnostics did not load. Check the
following items:
v
The bootlist on the client may be incorrect.
v
Cstate on the NIM server may be incorrect.
v
There may be network problems preventing you from connecting to the NIM server.
Verify the settings and the status of the network. If you continue to have problems, refer
to the
Boot Problems and Concerns section of the
Eserver
pSeries 670 Service Guide
and follow the steps for network boot problems.
After running diagnostics, reboot the system and use SMS to change the bootlist
sequence back to the original settings.
82
Eserver
pSeries 670 User’s Guide
Summary of Contents for Eserver pSeries 670
Page 1: ...pSeries 670 User s Guide SA38 0614 00 ERserver IBM...
Page 2: ......
Page 3: ...pSeries 670 User s Guide SA38 0614 00 ERserver IBM...
Page 14: ...xii Eserver pSeries 670 User s Guide...
Page 22: ...6 Eserver pSeries 670 User s Guide...
Page 28: ...12 Eserver pSeries 670 User s Guide...
Page 88: ...72 Eserver pSeries 670 User s Guide...
Page 136: ...120 Eserver pSeries 670 User s Guide...
Page 150: ...134 Eserver pSeries 670 User s Guide...
Page 154: ...138 Eserver pSeries 670 User s Guide...
Page 158: ...142 Eserver pSeries 670 User s Guide...
Page 188: ...172 Eserver pSeries 670 User s Guide...
Page 194: ...178 Eserver pSeries 670 User s Guide...
Page 197: ......