1. Open the Subsystem Management window.
2. Select the component button for each storage expansion enclosure in this
storage subsystem, and view the status of each of the components.
The status for each component is either Optimal or Needs Attention.
3. Does any component have a Needs Attention status?
v
Yes
- Go to step 4.
v
No
- All components are Optimal. Go to step 6.
4. Select the Recovery Guru toolbar button. Perform the procedure in the
Recovery Guru to correct the problem. The Recovery Guru might direct you to
replace the failed component. If so, go to step 5.
Attention:
If the fault requires you to power off an attached storage expansion
enclosure, you might need to cycle the power on the DS4000 storage
subsystem and all remaining storage expansion enclosures in the storage
subsystem. Contact IBM Customer and Technical Support before powering off
any attached storage expansion enclosures.
5. If applicable, mute the alarm.
6. Check the indicator LEDs on the front and the back of the storage expansion
enclosure.
A green LED denotes a normal status; an amber LED denotes a hardware fault.
7. Is an amber LED on?
v
Yes
- Locate and troubleshoot the failed components. See “Checking the
v
No
- You are finished with this procedure. If you are still experiencing a
problem with this storage subsystem, create, save, and print a storage
subsystem profile. This information might be helpful when troubleshooting.
Contact IBM Customer and Technical Support for assistance. When the
recovery procedure is completed, select
Recheck
in the Recovery Guru to
rerun the Recovery Guru and to ensure that the problem has been corrected.
Checking the LEDs
The LEDs display the status of the storage subsystem and components. The color
of the LED is important.
v
Green LEDs indicate a normal operating status
v
Amber LEDs (Needs Attention) indicate a possible failure
v
Blue LED on a CRU indicates that is safe to remove the component
The DS4700 Express Storage Subsystem also has a blue Global Locate LED that
is lit when the menu function is selected in the Subsystem Management window,
causing the LOCATE command to be sent to the DS4700 Express.
It is important to check all the LEDs on the front and back of the storage subsystem
when you turn on the power. During power up, the indicator LEDs blink
intermittently as the storage subsystem and components complete the power-up
process. In addition to checking for faults, you can use the LEDs on the front of the
storage subsystem to determine if the drives are responding to I/O transmissions
from the host.
Chapter 4. Operating the storage subsystem
125
Summary of Contents for DS4700 EXPRESS
Page 2: ......
Page 269: ......
Page 270: ...Part Number 94Y8472 Printed in USA GC26 7843 05 1P P N 94Y8472...