Removing
and
replacing
Tier
1
CRUs
Replacement
of
Tier
1
CRUs
is
your
responsibility.
If
IBM
installs
a
Tier
1
CRU
at
your
request,
you
will
be
charged
for
the
installation.
The
illustrations
in
this
document
might
differ
slightly
from
your
hardware.
Removing
the
DPI
blade
from
the
BladeCenter
unit
The
following
illustration
shows
how
to
remove
a
DPI
blade
from
a
BladeCenter
H
or
HT
unit.
The
appearance
of
your
BladeCenter
unit
might
be
different.
See
the
documentation
for
your
BladeCenter
unit
for
additional
information.
Attention:
v
To
maintain
proper
system
cooling,
do
not
operate
the
BladeCenter
unit
without
a
blade
server,
DPI
blade,
or
filler
installed
in
each
blade
bay.
v
When
you
remove
the
DPI
blade,
note
the
bay
number.
Reinstalling
a
DPI
blade
into
a
different
bay
from
the
one
it
was
removed
from
can
have
unintended
consequences.
Some
configuration
information
and
update
options
are
established
according
to
bay
number;
if
you
reinstall
the
DPI
blade
into
a
different
bay,
you
might
have
to
reconfigure
the
DPI
blade.
To
remove
the
DPI
blade,
complete
the
following
steps:
1.
If
the
DPI
blade
is
operating,
unbind
it
from
the
ASM.
This
turns
off
the
DPI
blade.
If
the
DPI
blade
is
not
bound
or
assigned,
press
the
power-control/unbind
button
(behind
the
DPI
blade
control
panel
door)
to
turn
off
the
DPI
blade.
See
and
for
more
information.
2.
Open
the
two
release
handles
as
shown
in
the
illustration.
The
DPI
blade
moves
out
of
the
bay
approximately
0.6
cm
(0.25
inch).
3.
Pull
the
DPI
blade
out
of
the
bay.
4.
Place
either
a
filler
or
another
blade
in
the
bay
within
1
minute.
5.
If
you
are
instructed
to
return
the
DPI
blade,
follow
all
packaging
instructions,
and
use
any
packaging
materials
for
shipping
that
are
supplied
to
you.
Chapter
4.
Removing
and
replacing
DPI
blade
components
27