Step 2. Loading the Diagnostics
1. Stop all application programs running on the operating system.
2. Stop the operating system.
3. Turn the power off.
4. If you are loading the Standalone Diagnostics and running them from an ASCII
terminal, do the following:
The attributes for the terminal must be set to match the defaults of the
diagnostics.
If you need to change any settings, record the normal settings, and be sure
the terminal attributes are set to work with the diagnostics. If needed, see
“Running the Diagnostics from a TTY Terminal” on page 5-3.
Proceed to substep 5 when you finish checking the attributes.
5. Turn the power on.
a. When the
Keyboard
indicator appears, press the 5 key on the keyboard to
load the Standalone Diagnostics or press the 6 key to load the Online
Diagnostics.
b. Enter any requested passwords.
c. Follow the instructions to select a console.
6. When the Diagnostic Operating Instructions display, go to “Step 3. Running
System Verification” on page 7-3. If you are unable to load the diagnostics, go
to “Problem Determination When Unable to Load Diagnostics” on page 8-11.
7-2
7046 Model B50 User's Guide
Summary of Contents for B50
Page 1: ...RS 6000 7046 Model B50 IBM User s Guide SA38 0563 00 ...
Page 2: ......
Page 3: ...RS 6000 7046 Model B50 IBM User s Guide SA38 0563 00 ...
Page 6: ...iv 7046 Model B50 User s Guide ...
Page 20: ...xviii 7046 Model B50 User s Guide ...
Page 32: ...1 10 7046 Model B50 User s Guide ...
Page 52: ...2 20 7046 Model B50 User s Guide ...
Page 152: ...6 6 7046 Model B50 User s Guide ...
Page 172: ...8 16 7046 Model B50 User s Guide ...
Page 208: ...9 36 7046 Model B50 User s Guide ...
Page 216: ...X 6 7046 Model B50 User s Guide ...
Page 219: ......
Page 221: ...Spine information IBM RS 6000 7046 Model B50 User s Guide ...