Table 3. SPCN Error Codes for I/O Subsystems (continued)
Error Code Description
Action/
Possible Failing FRU
1nn1 1B03 +3.3 V load fault
1. Replace power supply 1, U0.
dd
-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 1B04 -12 V load fault
1. Replace power supply 1, U0.
dd
-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.
dd
-P1.
1nn1 2600 Pgood fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 2603 Power domain fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 2605 Pgood 1.8 V fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 2606 Pgood 2.5 V fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3100 I2C controller fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3101 I2C bus fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3102 I2C interface fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3103 I2C interface fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3104 I2C interface fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3110 SES module fault on SCSI backplane 1
Replace the SCSI backplane, location: U0.
dd
-P3
1nn1 3111 SES module fault on SCSI backplane 2
Replace the SCSI backplane, location: U0.
dd
-P4
1nn1 3113 PCI bridge chip fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3114 I2C fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3115 Operator panel fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3118 SPCN VPD fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 3121 I2C VPD fault
I/O subsystem backplane, U0.
dd
-P1.
1nn1 7610 Blower 1 fault
Blower 1, U0.
dd
-F1.
1nn1 7611 Blower 1 missing
Blower 1, U0.
dd
-F1.
1nn1 7620 Blower 2 fault
Blower 2, U0.
dd
-F2.
1nn1 7621 Blower 2 missing
Blower 2, U0.
dd
-F2.
1nn1 7630 Blower 3 fault
Blower 3, U0.
dd
-F3.
1nn1 7631 Blower 3 missing
Blower 3, U0.
dd
-F3.
1nn1 7640 Blower 4 fault
Blower 4, U0.
dd
-F4.
1nn1 7641 Blower 4 missing
Blower 4, U0.
dd
-F4.
1nn1 8400 Configuration ID conflict
1. Check the RIO and the SPCN cabling.
2. Set the I/O type using the service processor
menus.
3. I/O subsystem backplane, U0.
dd
-P1.
224
Eserver
pSeries 630 Model 6C4 and Model 6E4 Service Guide
Summary of Contents for @Server pSeries 630 6E4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 03 ERserver ...
Page 16: ...xiv Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 18: ...xvi Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 382: ...362 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 440: ...420 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 538: ...System Parts continued 518 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 541: ...Chapter 10 Parts Information 521 ...
Page 562: ...542 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 568: ...548 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 576: ...556 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 580: ...560 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 616: ...596 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 646: ...626 Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide ...
Page 649: ......