About this task
To configure the Virtual I/O Server system for identifying a part, complete the following steps:
Procedure
1.
Log in as root user or enter the command:
celogin-
2.
On the command line, enter the following command:
diagmenu
3.
From the Function Selection menu, select Task Selection.
4.
Select Display Previous Diagnostic Results.
5.
From the Display Previous Diagnostic Results display, select Display Diagnostic Log Summary. A
Display Diagnostic Log
display appears. This display contains a chronological list of events.
6.
Look in the T column for the most recent S entry. Select this row in the table and press Enter.
7.
Choose Commit. The details of this log entry are shown.
8.
Record the location information and the service request number (SRN) value shown near the end of
the entry.
9.
Exit to the command line.
Results
Use the location information for the part to activate the indicator light that identifies the part. For
instructions, see “Activating the indicator light for a part by using the VIOS tools.”
Activating the indicator light for a part by using the VIOS tools:
You can use Virtual I/O Server (VIOS) tools to activate the indicator light to physically locate a part.
About this task
To turn on the indicator light for identifying a part, complete the following steps:
Procedure
1.
Log in as root user.
2.
On the command line, enter the following command:
diagmenu
3.
From the Function Selection menu, select Task Selection.
4.
From the Task Selection menu, select Identify and Attention Indicators.
5.
From the list of lights, select the location code for the failing part and press Enter.
6.
Select Commit. Look for the blue indicator LED on the system to identify the enclosure that contains
the part.
Important:
A flashing amber LED indicates the location of the part and a solid amber LED indicates
that the part is failing.
7.
Exit to the command line.
Identifying a part by using the ASMI
Learn how to activate or deactivate amber identify indicator light-emitting diodes (LEDs) by using the
Advanced System Management Interface (ASMI).
32
Power Systems: System processor modules for the 9008-22L, 9009-22A, or 9223-22H
Summary of Contents for 9008-22L
Page 1: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Page 2: ......
Page 3: ...Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H IBM...
Page 16: ...xiv Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Page 108: ...92 Power Systems System processor modules for the 9008 22L 9009 22A or 9223 22H...
Page 109: ......
Page 110: ...IBM...