v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8872
and
Type
8874,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
166-201-007
ISMP
indicates
I2C
errors
on
bus
M0.
1.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
166-201-008
ISMP
indicates
I2C
errors
on
bus
M1.
1.
Reseat
the
following
components:
a.
Memory
card
b.
I/O
board
c.
Microprocessor
tray
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
166-260-000
ASM
restart
failure.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
3.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-342-000
System
management
BIST
indicates
failed
tests.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Reseat
the
Remote
Supervisor
Adapter
II
SlimLine.
3.
Replace
the
Remote
Supervisor
Adapter
II
SlimLine.
166-400-000
ISMP
Self
Test
Result
failed
tests:
xxx
where
xxx=flash,
ROM,
or
RAM.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Update
the
BMC
firmware
(see
“Updating
the
firmware”
on
page
133).
3.
Reseat
the
I/O
board.
4.
Replace
the
I/O
board.
Chapter
2.
Diagnostics
71