v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
mouse
or
pointing
device
does
not
work.
v
Make
sure
that
the
mouse
or
pointing-device
cable
is
securely
connected
to
the
server
and
that
the
keyboard
and
mouse
cables
are
not
reversed.
v
Make
sure
that
the
mouse
device
drivers
are
installed
correctly.
v
Try
using
another
mouse
or
pointing
device.
If
the
problem
remains,
call
for
service.
Memory
problems
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Symptom
Action
The
amount
of
system
memory
displayed
is
less
than
the
amount
of
installed
physical
memory.
Make
sure
that:
v
The
DIMMs
are
seated
correctly.
v
You
have
installed
the
correct
type
and
capacity
of
memory.
v
You
have
installed
the
DIMMs
in
the
correct
slots,
in
the
correct
order.
v
If
you
changed
the
memory,
you
updated
the
memory
configuration
in
the
Configuration/Setup
Utility
program.
v
All
banks
of
memory
are
enabled.
The
server
might
have
automatically
disabled
a
memory
bank
when
it
detected
a
problem,
or
a
memory
bank
might
have
been
manually
disabled.
Look
in
the
POST
error
log
for
error
message
289:
v
If
the
DIMM
was
disabled
by
a
system-management
interrupt
(SMI),
replace
the
DIMM.
v
If
the
DIMM
was
disabled
by
the
user
or
by
POST,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
v
If
this
error
remains,
replace
the
DIMM.
If
the
problem
remains,
call
for
service.
Chapter
6.
Solving
problems
55
Summary of Contents for 8863 - eServer xSeries 366
Page 3: ...IBM xSeries 366 Type 8863 Installation Guide...
Page 18: ...6 IBM xSeries 366 Type 8863 Installation Guide...
Page 58: ...46 IBM xSeries 366 Type 8863 Installation Guide...
Page 60: ...48 IBM xSeries 366 Type 8863 Installation Guide...
Page 78: ...66 IBM xSeries 366 Type 8863 Installation Guide...
Page 88: ...76 IBM xSeries 366 Type 8863 Installation Guide...
Page 92: ...80 IBM xSeries 366 Type 8863 Installation Guide...
Page 93: ......
Page 94: ...Part Number 31R1515 Printed in USA 1P P N 31R1515...