When you set the Action field of the backup port pair to ACTIVE, the
status field will then change from being blank to either STAND-BY or
BACKUP. STAND-BY indicates that the primary port is functioning and
enabled. BACKUP means that the primary port has failed and the
secondary port has taken over. To reset a backup pair so that the
primary port is again handling network traffic, reset the Action field to
ACTIVE.
Note: If a port has been configured for intrusion protection, that function
has priority. This means that a port configured as the secondary that has
been disabled as the result of an intrusion violation will not be available
should the primary port with which it is paired fail.