Replacing a part by using the Systems Director Management Console
You can use the IBM Systems Director Management Console (SDMC) to perform many service actions,
including exchanging a field replaceable unit (FRU) or part.
If you are exchanging a part to repair a serviceable event follow those instructions.
1.
In the Power Systems Resource area, select the managed system in which you are exchanging a part.
2.
Select one of the following options:
v
If you are replacing a part that is not part of a serviceable event, from the
Actions
menu, expand
Service and Support
→
Hardware
→
Exchange FRU
.
v
If you are exchanging a part to repair a serviceable event, see Starting a repair action.
3.
To replace a part as part of a service action, select
Exchange FRU
.
4.
From the Exchange FRU tab, select the system or expansion unit in which you want to exchange a
part.
5.
Select the type of part you want to exchange from the menu and click
Next
.
6.
Select the location code of the part you want to exchange from the menu and click
Add
.
7.
After the FRU is placed in the
Pending actions
window, click
Launch Procedure
and follow the
instructions to exchange the part.
Note:
The SDMC might open external instructions for replacing the part. If so, follow those
instructions to replace the part.
66
Control panel, control panel fillers, and signal cables
Summary of Contents for 8203-E4A
Page 1: ...Power Systems Control panel control panel fillers and signal cables ...
Page 2: ......
Page 3: ...Power Systems Control panel control panel fillers and signal cables ...
Page 10: ...2 Control panel control panel fillers and signal cables ...
Page 32: ...24 Control panel control panel fillers and signal cables ...
Page 81: ......
Page 82: ... Printed in USA ...