v
No:
If a service request number (SRN) or other reference code is displayed, suspect a loose adapter
or cable connection. Review the installation procedures to ensure that the new feature is installed
correctly. If you cannot correct the problem, collect all SRNs or any other reference code
information that you see. If the system is running in logical partitioning (LPAR) mode, note the
logical partition in which you installed the feature. Contact your service provider for assistance.
v
Yes:
The new device is installed correctly. Exit the diagnostic programs and return the system to
normal operations.
Verify the replacement part using AIX:
To verify the operation of a newly installed feature or replacement part, follow these steps:
1.
Did you use either the AIX operating system or the online diagnostics service aid concurrent
(hot-swap) service to replace the part?
No:
Go to step 2.
Yes:
Go to step 5.
2.
Is the system powered off?
No:
Go to step 4.
Yes:
If the system supports slow boot, set the system to perform a slow boot. For information, see
3.
Start the system and wait until the AIX operating system login prompt is displayed or until apparent
system activity on the operator panel or display has stopped.
Did the AIX login prompt display?
v
No:
If a service request number (SRN) or other reference code is displayed, suspect a loose
adapter or cable connection. Review the procedures for the part that you replaced to ensure that
the new part is installed correctly. If you cannot correct the problem, collect all SRNs or any other
reference code information that you see. If the system does not start or you have no login prompt,
see: Problems with loading and starting the operating system.
If the system is partitioned, note the logical partition in which you replaced the part. Contact your
service provider for assistance.
v
Yes:
Go to step 4.
4.
At the command prompt, type
diag —a
and press Enter to check for missing resources. If you see a
command prompt, go to step 5.
If the
Diagnostic selection
menu is shown with
M
appearing next to any resource, follow these
steps:
a.
Select the resource and press Enter.
b.
Select
Commit
.
c.
Follow any instructions that are shown.
d.
If the
Do you want to review the previously displayed error?
message is shown, select
Yes
and press
Enter.
e.
If an SRN is shown, suspect a loose card or connection. If no obvious problem is shown, record
the SRN and contact your service provider for assistance.
f.
If no SRN is shown, go to step 5.
5.
Test the part by doing the following steps:
a.
At the command line, type
diag
and press Enter.
b.
From the
Function Selection
menu, select
Advanced Diagnostics Routines
and press Enter.
c.
From the
Diagnostic Mode Selection
menu, select
System Verification
and press Enter.
d.
Select
All Resources
, or select the diagnostics for the individual part to test only the part you
replaced and any devices that are attached to the part you replaced and press Enter.
Did the
Resource Repair Action
menu appear?
Chapter 3. Common procedures for installable features
53
Summary of Contents for 8203-E4A
Page 1: ...Power Systems Control panel control panel fillers and signal cables ...
Page 2: ......
Page 3: ...Power Systems Control panel control panel fillers and signal cables ...
Page 10: ...2 Control panel control panel fillers and signal cables ...
Page 32: ...24 Control panel control panel fillers and signal cables ...
Page 81: ......
Page 82: ... Printed in USA ...