By default, the managed system is set to power off automatically when you shut down the last running
logical partition on the managed system. If you set the managed system properties on the HMC so that
the managed system does not power off automatically, you must use this procedure to power off your
managed system.
Attention:
If possible, shut down the running logical partitions on the managed system before powering
off the managed system. Powering off the managed system without shutting down the logical partitions
first causes the logical partitions to shut down abnormally and can cause data loss. If you use a Virtual
I/O Server (VIOS) logical partition, ensure that all clients are shut down or that the clients have access to
their devices using an alternate method.
To power off a managed system, you must be a member of one of the following roles:
v
Super administrator
v
Service representative
v
Operator
v
Product engineer
1.
In the Navigation area, expand the
Systems Management
folder.
2.
Click the
Servers
icon.
3.
In the Contents area, select the managed system.
4.
Select
Tasks
, then
Operations
, and then
Power Off
5.
Select the appropriate power-off mode and click
OK
.
Related information
Shutting down and restarting logical partitions
Stopping a system with the Systems Director Management Console
You can use the IBM Systems Director Management Console (SDMC) user interface to stop the system or
a virtual server. Use the following steps to accomplish this task.
By default, the managed system is set to power off automatically when you shut down the last running
virtual server on the managed system. If you set the managed system properties on the SDMC so that the
managed system does not power off automatically, you must use this procedure to power off your
managed system.
Attention:
If possible, shut down the running virtual servers on the managed system before powering
off the managed system. Powering off the managed system without shutting down the virtual servers
first causes the virtual servers to shut down abnormally and can cause data loss. If you use a Virtual I/O
Server (VIOS) logical partition, ensure that all clients are shut down or that the clients have access to
their devices with an alternate method.
To power off a managed system, you must be a member of one of the following roles:
v
Super administrator
v
Service representative
v
Operator
v
Product engineer
1.
In the Power Systems
™
Resource area, select the managed system you want to power off.
2.
From the
Actions
menu, select
Operations
→
Power Off
.
3.
Select the appropriate power-off mode and click
OK
.
32
Control panel, control panel fillers, and signal cables
Summary of Contents for 8203-E4A
Page 1: ...Power Systems Control panel control panel fillers and signal cables ...
Page 2: ......
Page 3: ...Power Systems Control panel control panel fillers and signal cables ...
Page 10: ...2 Control panel control panel fillers and signal cables ...
Page 32: ...24 Control panel control panel fillers and signal cables ...
Page 81: ......
Page 82: ... Printed in USA ...