3.
Check the power cord for the following:
a.
A third-wire ground connector in good condition. Use a meter to measure
third-wire ground continuity for 0.1 ohm or less between the external
ground pin and frame ground.
b.
The power cord should be the appropriate type as specified in the parts
listings.
c.
Insulation must not be frayed or worn.
4.
Remove the cover.
5.
Check for any obvious non-IBM alterations. Use good judgment as to the safety
of any non-IBM alterations.
6.
Check inside the unit for any obvious unsafe conditions, such as metal filings,
contamination, water or other liquids, or signs of fire or smoke damage.
7.
Check for worn, frayed, or pinched cables.
8.
Check that the power-supply cover fasteners (screws or rivets) have not been
removed or tampered with.