POST Error Code
FRU/Action
16XX
1.
36/38 Workstation Adapter
1762
Hard disk drive configuration error
1.
Run Configuration. (See “Setup Utility
program” on page 7.)
1780
(Disk Drive 0)
1781
(Disk Drive 1)
1782
(Disk Drive 2)
1783
(Disk Drive 3)
1.
See “Power supply” on page 33.
2.
Hard Disk Drive
3.
System Board
4.
Riser card
5.
Hard Disk Cable
6.
Power Supply
180X, 188X
PCI configuration or resource error
1.
Run Setup and verify PCI/ISA
configuration settings.
2.
If necessary, set ISA adapters to
Not
available
to allow PCI adapters to
properly configure.
3.
Remove any suspect ISA adapters.
4.
Rerun diagnostics.
5.
PCI Adapter
1962
Boot sequence error
1.
Possible hard disk drive problem; see
“Hard disk drive boot error” on page
38.
209X
1.
Diskette Drive
2.
Diskette Cable
20XX
Not listed above
1.
BSC Adapter
21XX
1.
SCSI Device
2.
16-bit AT Fast SCSU adapter
3.
Alternate BSC adapter
2401, 2402
If screen colors change
1.
Display
2401, 2402
If screen colors are OK
1.
System Board
2.
Display
2409
1.
Display
2410
1.
System Board
2.
Display
2462
Video memory configuration error
1.
Check cable connections
2.
Run Setup and verify video
configuration settings
3.
Video Memory Modules
4.
Video Adapter (if installed)
5.
System Board
4611, 4630
1.
Multiport/2 Interface Board
2.
Multiport/2 Adapter
Chapter 6. Symptom-to-FRU Index
65
Summary of Contents for 6840GAU - NetVista A40 - 6840
Page 1: ...Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271 IBM NetVista Computer...
Page 2: ......
Page 3: ...Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271 IBM NetVista Computer...
Page 41: ...4 Remove the power supply Chapter 5 FRU Replacements 35...
Page 113: ...Chapter 10 Related Service Information 107...
Page 115: ...Chapter 10 Related Service Information 109...
Page 125: ...Chapter 10 Related Service Information 119...
Page 127: ...Chapter 10 Related Service Information 121...
Page 147: ......
Page 148: ...Part Number 06P1775 Printed in USA 1P P N 06P1775...