v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, System x3200 M2 Types 4367 and 4368,” on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
175
Service processor flash code damaged or
not loaded.
1. Update the Remote Supervisor Adapter II
SlimLine firmware.
2. Replace the Remote Supervisor Adapter II
SlimLine.
178
Security hardware error.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
2. (Trained service technician only) Replace the
system board.
184
Power-on password damaged.
1. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
2. Reseat the battery.
3. Clear CMOS. See “System-board jumpers” on
page 13 for information about how to clear
CMOS.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
187
VPD serial number not set.
1. Set the serial number by updating the BIOS code
level (see “Updating the firmware” on page 15).
2. (Trained service technician only) Replace the
system board.
188
Service processor firmware corrupted or not
installed.
1. Restart the server.
2. Run the Configuration/Setup Utility program,
select
Load Default Settings
, and save the
settings.
3. Update the Remote Supervisor Adapter II
SlimLine firmware (see“Updating the firmware” on
page 15).
4. (Trained service technician only) Replace the
system board.
189
Three attempts were made to access the
server with an incorrect password.
Restart the server and enter the administrator
password; then, run the Configuration/Setup Utility
program and change the power-on password.
289
A DIMM has been disabled by system.
1. Make sure that the DIMM is installed correctly
(see “Installing a memory module” on page 76).
2. Replace the DIMM.
3. (Trained service technician only) Replace the
system board.
Chapter 5. Diagnostics
129
Summary of Contents for 4367
Page 1: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 2: ......
Page 3: ...System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 32: ...14 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 50: ...32 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 64: ...46 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 138: ...120 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 258: ...240 System x3200 M2 Types 4367 and 4368 Problem Determination and Service Guide ...
Page 265: ......
Page 266: ... Part Number 49Y0163 Printed in USA 1P P N 49Y0163 ...