v
“Upgrading the device’s monitor and boot images” on page 52 - This subsection
describes the procedures required for upgrading the c-series switches Monitor
and Boot software images. The procedures described apply to all versions of the
software.
v
“Upgrading the multi-service IronWare image” on page 51 - This subsection
describes the procedures required for upgrading the c-series switches
Multi-Service IronWare software image. The procedures described apply to all
versions of the software.
v
“Scheduling a system reload” on page 57 - This subsection describes the
procedures required for reloading the system after upgrading the software
images.
Description of the software images required
The functionality within each of the software images required to operate the
c-series switches is described in Table 11. Because the functions that are most likely
to change are contained within the Multi-Service IronWare image, updates will
usually only require updating the Multi-Service IronWare image. The initial release
of the c-series switches supports Multi-Service IronWare version R03.8.00c. For the
latest support information, please visit the Ethernet products support web-site.
Table 11. Description of software images
Software Image
Functions in versions 03.8.00
and later
Image Name
Boot Image
Bootstrap
ceb<
xxxx
>
Monitor Image
Image Handling
Memory Init
ceb<
xxxx
>
Multi-Service IronWare
Image
Application
OS
ce<
xxxx
>
Note:
The c-series switches use the same file image for both the boot and monitor
images.
Upgrading the multi-service IronWare software
When performing this upgrade, you will usually only need to upgrade
Multi-Service IronWare image. The Boot and Monitor images will only need to be
upgraded as specifically directed in the relevant release notes.
The steps for this upgrade include the following:
1.
Determine the versions of the software images currently installed and running
on the switch.
2.
Upgrade the device’s Multi-Service IronWare Image.
3.
Reboot the switch.
In most cases, this is all that will be required. If you are directed by the release
notes to upgrade the Monitor or Boot images, use the following procedures:
1.
Upgrade the monitor and boot images of the switches.
Use the procedures described in “Upgrading the device’s monitor and boot
images” on page 52.
2.
Reboot the switch.
48
IBM Ethernet Switch c-series Installation and User Guide
Summary of Contents for 4002-C2A
Page 2: ......
Page 10: ...viii IBM Ethernet Switch c series Installation and User Guide...
Page 12: ...x IBM Ethernet Switch c series Installation and User Guide...
Page 26: ...xxiv IBM Ethernet Switch c series Installation and User Guide...
Page 28: ...2 IBM Ethernet Switch c series Installation and User Guide...
Page 43: ...net48bc017 Figure 11 Front rack mount position Chapter 3 Installation 17...
Page 45: ...net48bc019 Figure 13 Mid rack mount position Chapter 3 Installation 19...
Page 64: ...38 IBM Ethernet Switch c series Installation and User Guide...
Page 86: ...60 IBM Ethernet Switch c series Installation and User Guide...
Page 97: ......
Page 98: ...Part Number 45W5355 Printed in USA GC27 2238 01 1P P N 45W5355 53 1001492 01...