IBML
Installation Instructions
11.9.2 TCM Enclosure
1. Place the TCM enclosure on the shipping
pallet assembly provided with the new
enclosure.
2. Secure it with the screws and nuts.
3. Remove the bracket locking the STER
cards in the TCM enclosure by removing
2 screws.
4. Open carefully the ZIF connectors on all
cards.
Notes:
a. For US, remove all the cards from
the CCU enclosure, and put them in
ESD envelopes and containers pro-
vided by the MES.
b. For EMEA, remove the storage cards
from the CCU enclosure, and put
them in ESD envelopes and con-
tainers provided by the MES.
5. Install the red bracket removed in Step
10.4.3.3 over the CCU cards, and secure
it with 4 screws.
6. Follow the re-packing instructions to
send parts back to IBM.
After Installation (steps 12-15)
12.0 Field Updating
None.
13.0 Publications Update
None.
14.0 Parts Disposition
•
For parts listed in the RMER
All these parts become the property of IBM.
You MUST RETURN these parts following the
instructions given on the Returned Material
Equipment Report (RMER) provided with this
FFBM.
•
For parts not listed in the RMER
All these parts should be returned according
to your local procedure.
15.0 Machine Records
•
Install the new MACHINE HISTORY supplied.
•
Report installation (As MES activity) and
quality to existing procedures.
End of instructions.
3745
PN 17G5534
EC C38405
EC C38405A
EC D55799
EC D55883
EC E27926
FFBM
22 of 22
06APR93
17JUN93
16SEP94
11MAY95
14MAR97
22