Error Code/Symptom
FRU/Action
E704 Fan Failure
(In a non-fatal situation , a
fan has failed. If multiple
fans fail, the enclosure is
shutdown and the enclosure
will not run until the failure
is corrected.)
1. Fan
2. System Board (Planar)
E705 Overheat
(Power supply overheated
and the enclosure was
shutdown.)
1. Power Supply
2. Fan
3. System Board (Planar)
Blank information panel
(If the Power OK indicator is
on and the fans are running,
operation will probably not
be affected. However, no
diagnostic errors/messages
will be displayed.)
1. Information Display
Cable
2. Information Display
Assembly
3. System Board (Planar)
No power
(Be sure the power cords
and cables are properly
plugged in, the expansion
enclosure is properly
enabled and powered on,
and the electrical power
source is active.)
1. Power Cord
2. Power Supply
26
PC Server HMM