Step 15: AIX Diagnostics
This step runs the AIX diagnostics to determine the problem.
Run the diagnostics on the 7206 Tape Drive. Have the test cartridge (part number
59H4457) available for when the diagnostics prompt you to load the cartridge.
From the AIX command prompt, type:
diag
and then press Enter. For additional instructions on running diagnostics, refer to
your AIX manuals.
Do all of the diagnostics routines pass?
NO
Replace the FRU isolated by the diagnostics and identified by the service
request number.
Note:
If the drive is the FRU isolated by the diagnostics, check that the J1
connector is properly seated. If the drive has recently been replaced
because of a similar problem, contact your service personnel.
YES
If no problem was identified, the problem may be intermitant, related to
the tape quality, or relating to the environment. If a FRU was replaced or
changed and no more errors occur, the problem is fixed.
This completes the MAPs.
26
7206 Model 220 Service Guide
|
|
|
|
|
|
|
|
|