Symptom
Action
The
power-control
button
does
not
work
(the
server
does
not
start).
Note:
The
power-control
button
will
not
function
until
20
seconds
after
the
server
has
been
connected
to
ac
power.
1.
Make
sure
that
the
front-panel
assembly
power-control
button
is
working
correctly:
a.
Disconnect
the
server
power
cords.
b.
Reconnect
the
power
cords.
c.
Press
the
power-control
button.
d.
If
the
server
does
not
start,
bypass
the
front-panel
assembly
power-control
button
by
using
the
force
power-on
jumper
(see
the
Problem
Determination
and
Service
Guide
on
the
IBM
xSeries
Documentation
CD).
If
the
server
starts,
reseat
the
front-panel
assembly
cable
and
repeat
steps
1a
through
1c.
If
the
problem
remains,
replace
the
front-panel
assembly.
2.
Make
sure
that:
v
The
power
cords
are
correctly
connected
to
the
server
and
to
a
working
electrical
outlet.
v
The
server
contains
the
correct
type
of
DIMMs.
v
The
DIMMs
are
correctly
seated.
v
The
LEDs
on
the
power
supply
do
not
indicate
a
problem.
v
The
microprocessor
is
correctly
installed.
3.
Reseat
the
following
components:
a.
DIMMs
b.
Power
supply
cables
to
all
internal
components
c.
Power
supplies
(hot-swap
models)
4.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
DIMMs
b.
Power
supplies
(hot-swap
models)
c.
(Trained
service
technician
only)
Power
supply
(non-hot
swap
models)
5.
If
you
just
installed
an
optional
device,
remove
it,
and
restart
the
server.
If
the
server
now
starts,
you
might
have
installed
more
devices
than
the
power
supply
supports.
6.
See
“Solving
undetermined
problems”
in
the
Problem
Determination
and
Service
Guide
on
the
IBM
xSeries
Documentation
CD.
The
server
does
not
turn
off.
1.
Determine
whether
you
are
using
an
Advanced
Configuration
and
Power
Management
(ACPI)
or
a
non-ACPI
operating
system.
If
you
are
using
a
non-ACPI
operating
system,
complete
the
following
steps:
a.
Press
Ctrl+Alt+Delete.
b.
Turn
off
the
server
by
holding
the
power-control
button
for
5
seconds.
c.
Restart
the
server.
d.
If
the
server
fails
POST
and
the
power-control
button
does
not
work,
disconnect
the
ac
power
cord
for
20
seconds;
then,
reconnect
the
ac
power
cord
and
restart
the
server.
2.
(Trained
service
technician
only)
If
the
problem
remains
or
if
you
are
using
an
ACPI-aware
operating
system,
suspect
the
system
board.
Chapter
5.
Solving
problems
73
Summary of Contents for 206m - eServer xSeries - 8485
Page 3: ...xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 52: ...38 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 62: ...48 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 108: ...94 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 109: ......
Page 110: ... Part Number 40K2367 Printed in USA 1P P N 40K2367 ...