and
creating
a
RAID
level-1
logical
drive.
If
you
select
custom
configuration,
you
can
select
the
two
physical
drives
that
you
want
to
group
into
an
array
and
create
a
hot-spare
drive.
Using
express
configuration
To
use
express
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
From
the
toolbar,
click
Create
.
3.
Click
Express
configuration
.
4.
Click
Next
.
5.
In
the
“Configuration
summary”
window,
review
the
information.
To
change
the
configuration,
click
Modify
arrays
or
Modify
logical
drives
.
Note:
Some
operating
systems
have
size
limitations
for
logical
drives.
Before
you
save
the
configuration,
make
sure
that
the
size
of
the
logical
drive
is
appropriate
for
your
operating
system.
6.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
7.
Exit
from
ServeRAID
Manager
and
remove
the
CD
from
the
CD
drive.
8.
Restart
the
server.
Using
custom
configuration
To
use
custom
configuration,
complete
the
following
steps:
1.
In
the
ServeRAID
Manager
tree,
click
the
controller.
2.
From
the
toolbar,
click
Create
.
3.
Click
Custom
configuration
.
4.
Click
Next
.
5.
Click
the
applicable
tab
in
the
right
pane.
In
the
“Create
arrays”
window,
from
the
list
of
ready
drives,
select
the
two
drives
that
you
want
to
move
into
the
array.
6.
Click
the
icon
to
add
the
drives
to
the
array.
7.
If
you
want
to
configure
a
hot-spare
drive,
complete
the
following
steps:
a.
Click
the
Spares
tab.
b.
Select
the
physical
drive
that
you
want
to
designate
as
the
hot-spare
drive,
and
click
the
icon
to
add
the
drive.
8.
Click
Next
.
9.
In
the
“Configuration
summary”
window,
review
the
information.
To
change
the
configuration,
click
Back
.
10.
Click
Apply
;
when
you
are
asked
whether
you
want
to
apply
the
new
configuration,
click
Yes
.
The
configuration
is
saved
in
the
controller
and
in
the
physical
drives.
11.
Exit
from
ServeRAID
Manager,
and
remove
the
CD
from
the
CD
drive.
12.
Restart
the
server.
Viewing
the
configuration
You
can
use
ServeRAID
Manager
to
view
information
about
RAID
controllers
and
the
RAID
subsystem
(such
as
arrays,
logical
drives,
hot-spare
drives,
and
physical
46
xSeries
206m
Types
8485
and
8490:
Installation
Guide
Summary of Contents for 206m - eServer xSeries - 8485
Page 3: ...xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 52: ...38 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 62: ...48 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 108: ...94 xSeries 206m Types 8485 and 8490 Installation Guide ...
Page 109: ......
Page 110: ... Part Number 40K2367 Printed in USA 1P P N 40K2367 ...