background image

Version: 1.0

QuantaGrid Series

D51BP-1U

Energy Efficient 2-Socket Server with

Extreme Storage IOP/S

User’s Guide

Summary of Contents for D51BP-1U

Page 1: ...Version 1 0 QuantaGrid Series D51BP 1U Energy Efficient 2 Socket Server with Extreme Storage IOP S User s Guide ...

Page 2: ...n in this document is subject to change without notice The manufacturer makes no representations or warranties with respect to the contents hereof and specifi cally disclaims any implied warranties of merchantability or fitness for any particular pur pose Furthermore the manufacturer reserves the right to revise this publication and to make changes from time to time in the content hereof without o...

Page 3: ... 1 5 System Overview 1 5 System Front View 1 6 Front Control Panel 1 6 System Rear View 1 7 System Rear I O 1 7 Power Sub System 1 8 LED Status Definitions 1 9 Front Control Panel LED 1 9 LAN LED 1 10 BMC Management Port LED 1 10 HDD LED 1 10 Regulatory and Compliance Information ...

Page 4: ...ype face denotes keyboard keys Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES SIMILAR TO NOTES AND WARNINGS CAUTIONS HOWE...

Page 5: ...rviced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in related chapters to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product ...

Page 6: ...uppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power system because they serve as the product s main power disconnect Provided with either two independent DC power system or two independent phases from a single power system The enclosure is designed to carry only th...

Page 7: ...PARATE THE SYS TEM FROM THE POWER SOURCE CAUTION TO AVOID RISK OF ELECTRIC SHOCK DISCONNECT ALL CABLING FROM THE SYSTEM AND REMOVE THE SYSTEM FROM THE RACK CAUTION TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOLLOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF THE PRODUCT Disconnect from the power source by removing the system from the rack Disconnect all cabling running into t...

Page 8: ...ent If installed in a closed or multi unit rack assembly the oper ating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufac turer Reduced Air Flow Installation of the equipment in a rack should be such that the a...

Page 9: ...other resource as a reference pay close attention to the safety instructions Adhere to the assembly instructions in this manual to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components spec CAUTION ESD CAN DAMAGE DRIVES BOARDS AND OTHER PARTS WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION IF ONE IS NOT AVAI...

Page 10: ...ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers hav...

Page 11: ...trical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power system because they serve as the product s main power disconnect WARNING The system is safety cer...

Page 12: ...e Chapter 1 About the System This section introduces the system its different configuration s and the main features Chapter 2 Regulatory and Compliance Information This section provides regulatory and compliance information applicable to this system ...

Page 13: ...About the System Chapter 1 This section introduces the system its different configuration s and the main features ...

Page 14: ...Gb s of PCIe3 0x4 and the new inter face significantly reduces the latency caused by register access This solution effi ciently supports multi core architectures and SR IOV for data intensive virtualization workloads On QuantaGrid D51BP 1U all ten 2 5 front access drive bays support hot pluggable SATA SAS PCIe I O interface Owners can combine tra ditional hard disk drives and NVMe based SSDs to ta...

Page 15: ...10 RAID 6 with additional RAID key Networking LOM Option 1 Intel I350 dual port 1 GbE Dedicated 1 GbE management port Option 2 Intel X540 dual port 10 G BASE T Dedicated 1 GbE manage ment port Optional NIC more options refer to the CCL Quanta Intel I350 dual port OCP mezzanine Quanta Intel X540 dual port 10 G BASE T OCP mezzanine Quanta Intel 82599ES dual port 10G SFP OCP mezzanine Expansion slots...

Page 16: ...SU default with one PSU only detailed PSU options please refer to ordering info or CCL Fan 6x dual rotor fans 11 1 redundant System management IPMI v2 0 Compliant on board KVM over IP support Operating environment Operating temperature 5 C to 35 C 41 F to 95 F Non operating temperature 40 C to 65 C 40 F to 149 F Operating relative humidity 50 to 85 RH Non operating relative humidity 20 to 90 RH Ta...

Page 17: ...TS 1 4 1 2 Package Contents 1 D51BP 1U system 2 processor heat sinks 1 power supply unit 1 power cord optional 1 utility CD This Guide included 1 rail kit Note Note For exact shipping contents contact your Quanta sales representative ...

Page 18: ...MM slots 10 DDR4 DIMM slots 3 PSU assembly Redundant power supply unit assembly 4 Riser assembly Up to two x8 PCIe slots 5 Riser assembly 6 PSU assembly Redundant power supply unit assembly 7 Mainboard System mainboard 8 Backup battery Backup battery for mezzanine card 9 Front control panel See Front Control Panel on page 1 6 10 HDD assembly 10 x 2 5 storage device assemblies 11 Mid Top cover Hous...

Page 19: ... riser assembly available in certain models supporting low profile PCIe cards see item 5 in previous illustration Table 3 Front Panel View NO NAME DESCRIPTION 1 Front control panel See Front Control Panel LED on page 1 9 for further information 2 HDD bays 10 x2 5 SAS HDD SSD Table 4 Front Control Panel Definition NO ICON NAME DESCRIPTION 1 Reset button Soft reset system function 2 LAN2 LED LAN acc...

Page 20: ... ID LED 8 Power button Power on off Table 5 System Rear View NO FEATURE DESCRIPTION 1 Expansion slot PCIe expansion slot with PCIe x8 signal 2 Expansion slot 3 Power sub system Main power supply unit PSU1 See Power Sub System on page 1 8 4 System I O ports See System Rear I O on page 1 7 5 Power sub system Secondary power supply unit PSU2 See Power Sub System on page 1 8 Table 4 Front Control Pane...

Page 21: ...em Rear I O Defintition NO ICON NAME DESCRIPTION 1 OCP connector OCP debug connector optional 2 VGA connector Maximum display resolution 1920x1200 32bpp 60Hz reduced blanking 3 COM port A DB9 port Serial_A for debug or terminal concentrator 4 NIC2 RJ45 connector 5 NIC1 RJ45 connector 6 Dedicated NIC Dedicated RJ45 connector 7 USB ports USB ports 2 0 3 0 Table 7 Power Supply Units by Model PSU AC I...

Page 22: ...dentification Blue On Unit selected for identification Off No identification request Fault LED Amber Blinking Critical Failure critical fan voltage temperature state Non Critical Failure non critical fan voltage temperature state CPU thermal trip DC off Off SEL cleared Last pending warning or error has been de asserted HDD activity Blue Blinking Hard disk drive access only on board SATA port Off N...

Page 23: ...river is online and the slot is not empty Table 9 RJ45 LED Description CONDITION LINK ACTIVITY Unplugged Off Off 1G active link On amber Blinking green 100M active link On green Blinking green 10M active link Off Blinking green Table 10 BMC Management Port LED Behaviour NAME COLOR CONDITION BEHAVIOUR BMC Dedicated LAN Speed 1G Left LED Amber ON LAN link OFF No link Speed 100M Left LED Green ON LAN...

Page 24: ...FINITIONS 1 11 Only support SATA SAS HDD SSD HDD Activity Blue On HDD access is active Off No access HDD Fault Amber On HDD failure Off No failure detected Table 11 HDD LED Status Behavior Continued NAME COLOR CONDITION DESCRIPTION ...

Page 25: ...Regulatory and Compliance Information Chapter 2 This section provides regulatory and compliance information applicable to this system ...

Page 26: ......

Page 27: ... ...

Page 28: ... ...

Page 29: ......

Page 30: ... ...

Page 31: ... ...

Page 32: ...この裝置は クラス A 情報技術裝置です この裝置を家庭環境で使用すると電波 妨害を引き起こすことがあります この場合には使用者が適切な対策を講ずるよう 要求されることがあります VCCI A 警告使用者 此為甲類資訊技術設備 於居住環境使用中時 可能會造成 射頻擾動 在此種情況下 使用者會被要求採取某些適當的 對策 ...

Page 33: ...警告使用者 此為甲類資訊技術設備 於居住環境使用中時 可能會造成射頻擾動 在此種情況下 使用者會被要求採取某些 適當的對策 この裝置は クラス A 情報技術裝置です この裝置を家庭環境で使用すると電波妨害を引き起こすことがあります この場合に は使用者が適切な対策を講ずるよう要求されることがあります VCCI A ...

Page 34: ... ...