Table 13. POST conditions and results (continued)
Green LED
Yellow LED
State
Action to be taken
Slow flash
Fast flash
Restricted offline mode,
waiting for restart
None
Slow flash
Flashing
Restricted offline mode, test
active
None
Fast flash
Off
Debug monitor in restricted
mode
None
Fast flash
On
Not defined
None
Fast flash
Slow flash
Debug monitor in test fixture
mode
None
Fast flash
Fast flash
Debug monitor in remote
debug mode
None
Fast flash
Flashing
Not defined
None
Replacing Fibre Channel adapters by using hot swap
When hot swapping Fibre Channel adapters, be aware that device-related software for the storage devices
might have extra devices (for example, the disk array router (dar) device that is associated with the fiber
array storage technology (FAStT) or DS4800) that need to be removed. For more information, see the
specific storage device documentation for information about how to remove these additional devices.
The new adapter has a unique worldwide port name (WWPN). Check the zoning and logical unit
number (LUN) assignments to ensure that the new adapter functions as expected.
Operating system or partition requirements
If you are installing a new feature, ensure that you have the software that is required to support the new
feature and that you determine whether any prerequisites must be met for this feature and attaching
devices. To check for operating system and partition requirements, see one of the following links:
v
The latest version of enabling libraries and utilities can be downloaded from Fix Central
(http://www.ibm.com/support/fixcentral/).
v
IBM Power Systems Prerequisites (https://www14.software.ibm.com/support/customercare/iprt/
home).
v
IBM SSIC (System Storage Interoperation Center)(http://www-03.ibm.com/systems/support/storage/
ssic/interoperability.wss).
v
The latest version of the device driver or the IBM Power RAID adapter utilities (iprutils) can be
downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/
webapp/set2/sas/f/lopdiags/home.html).
v
For more information on Linux support, see the Linux Alert website(www14.software.ibm.com/
webapp/set2/sas/f/lopdiags/info/LinuxAlerts.html).
PCIe LP 4-Port Async EIA-232 Adapter (FC 5277; CCIN 57D2)
Learn about the features, operating system requirements, and installation procedures for the feature code
(FC) 5277 adapters.
Overview
The FC 5277 (PCIe LP 4-Port Async EIA-232 Adapter) is the low-profile version of the FC 5785 (4 Port
Async EIA-232 PCIe adapter), which is a full-height adapter.
Managing PCIe adapters
23
Summary of Contents for 000E9283
Page 2: ......
Page 16: ...xiv Managing PCIe adapters ...
Page 212: ...196 Managing PCIe adapters ...
Page 224: ...208 Managing PCIe adapters ...
Page 225: ......
Page 226: ...IBM ...