3
II. Specifications
Control mode ................................................................................................. Remote control
Remote control distance ................................................................................................. 20m
Output volume ..................................................................................................... 200m
3
/min.
Temperature ......................................................................................................... 260-280°C
Tank capacity ........................................................................................................... 1.2 liters
Heat-up time ......................................................................................................... 35-45 sec.
Appearance ...................................................................... metal shell, streamlined designs
IP grade .......................................................................................................................... IP22
Voltage ................................................................................................... AC 220-230V, 50Hz
Power ......................................................................................................................... 1500W
Fuse ............................................................................................................................ 10/15A
Dimensions ........................................................................................... 6 6 0 x 355 x 450mm
Weight ........................................................................................................................ 16.5kg
III. Installation
Add smoke oil
First loosen the cap of smoke oil can, take out the smoke oil tube. Then fill the smoke oil into the oil bottle.
After filling, drive tight the cap to avoid the oil leak out. You can also take out the oil bottle, then fill the
smoke oil, make sure the safety of the operator.
Warning
The power must be disconnected before adding the smoke oil
Please don’t let the smoke oil flow into the inside of the equipment to avoid short circuit.
Addition of ice
The generated smoke goes through ice which increases its weight.
Therefore the smoke remains longer on the ground to create a special
effect.
1. Unscrew the knobs on top of the cover
2. Pour the ice cubes on the white bracket
3. The maximum quantity of ice is 2.2kg
Please make sure that there is always enough ice in the compartment to
produce low fog.
In order to avoid overflowing of the melted ice, open the drain pump regularly
(every 10 minutes)
IV. Connection of Power and Wire
The exclusive wire should be used between the connection of the low fog machine and power. Please
confirm if the rated voltage and frequency are in accordance with the power supply.
Please contact the agent or professional for replacement if the power cable is damaged. The replaced
power cable must be same size as original.
Caution: The ground wire(Y/G wire) must be earthed during power connection; the installation must be in
accordance with specified standards.
Loosen
the cap of
smoke oil
bottle
Take out the
smoke oil tube