EN
GLISH
IBERITAL
89
INSTALLATION AND OPERATION MANUAL
Once this procedure is completed, press the
MENU
button to move on to the following option:
Steam Boiler Gr.
O/1/2
Option is not available
* The "STEAM BOILER" OPTION IS NOT AVAILABLE and will always leave the factory set at "O" (NOT AVAILABLE).
Once this procedure is completed, press the
MENU
button to move on to the following option:
PreBrewing
ENABLED/DISABLED
The display will give the option of ENABLING or DISABLING the "PRE-BREW" function using the UP/DOWN buttons.
ACTIVATING the "PRE-BREW" function and pressing the
MENU
button, the display will show:
PreBrew. ON
1 espresso xxxx sec
The display will show the timer option for ‘PRE-BREW ON’ for each coffee selection (1 espresso, 1 coffee, etc.). Pressing
the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the
MENU
button to select the ‘ON’ times for the rest of the selections.
Once this procedure is completed, press the
MENU
button to move on to the following option:
PreBrew. OFF
1 espresso xxxx sec
The display will show the ‘PRE-BREW’ timer ‘OFF’ option for each coffee selection (1 espresso, 1 coffee, etc.). Pressing
the UP/DOWN buttons, the desired time in seconds (from 0.1 sec. to 5 sec. in jumps of 0.1 sec.) can be selected. Press the
MENU button to select the ‘ON’ times for the rest of the selections.
Once this procedure is completed, press the MENU button to move on to the following option:
ProbeSensitivity
LOW/MID/HIGH
The display will show the "PROBE SENSITIVITY" option for the level of water in the boiler. Press the UP/DOWN buttons
to select low (150K
Ω
), medium (400K
Ω
) or high (1 M
Ω
) sensitivity.
Once this procedure is completed, press the MENU button to move on to the following option:
Service Cycles
xxxxxxx
The display will show the ‘SERVICE CYCLES’ option when the machine reaches the number of cycles selected. It will send
a visual alarm on the display as notification. Pressing the UP/DOWN keys selects the number of cycles.
Once this procedure is completed, press the MENU button to move on to the following option:
Heating Type
xxxxxxx
xxxxxx: Pressure Switch, ON/OFF, PID
The display will show the machine heating control system option.
Press the UP/DOWN buttons to select "
Pressure Switch
", "
ON/OFF
" or "
PID
" and confirm by pressing
OK
.
Summary of Contents for IB7