INSTALLATION AND OPERATION MANUAL
ATTENTION
If the water quantity is left at zero "0" litres, the option will be DISABLED.
Lastly, press the
MENU
button to exit the
TECHNICAL MENU
.
Off hh.mm
2.9.3.1.3. Display alarm signals
A. MAXIMUM FILLING TIME FOR BOILER WATER
When a time set by the manufacturer is exceeded, the display will show:
Time-out alarm
Boiler fillingUp
at the same time, the button LEDs begin to flash.
To cancel the alarm, the main switch must be set to O and then to 1.
B. MAXIMUM BOILER TEMPERATURE
The display will show the boiler temperature alarm when it exceeds 140ºC for more than 5 seconds.
Alarm
Boiler temperature
The alarm will disappear when the boiler temperature returns to its normal values.
C. INTERRUPTED TEMPERATURE SENSOR
- When the sensor detects a temperature of 0ºC for 5 seconds, the LEDs on the button pads will flash and the display
will show:
T.ProbeUnconnect
The alarm will disappear when the boiler temperature is once again at an acceptable value.
- In the case of the control unit being replaced, a machine with a display and pressure switch will display:
T.ProbeUnconnect
This situation is due to an incorrect selection on the heating menu (reprogram the control unit). (SEE PROGRAMMING IN
SECTION 2.9.3.2.3., HEATING MENU OPTION.)
In order to eliminate this alarm: