SAS0922

Page 

4

LOCATION  &  INSTALLATION

1.

The  softener  requires  an  inlet  water  pressure  between  140kPa  (20psi)  and  690kPa
(100psi).

2. 

The softener should service all water lines in the house except the toilet and outside taps.
The  softener  should  be  positioned  on  a  level  flat  surface  close  to  a  drain  or  any  other
properly trapped waste outlet.

The brass adaptors supplied are suitable for 20mm (3/4") female fittings and the softener
should  be  connected  to  the  supply  with  raw  water  to  the  inlet  connector  and  softened
water lines to the outlet as indicated on the valve.

3. 

When facing the front of the control the inlet is to the right and the outlet is to the left.

4. 

The system pressure must be between 140 kPa and 690 kPa psi.

5. 

If the system pressure is greater than 690kPa psi a 

pressure  reducing  valve

  must  be

installed.

6. 

The unit must be installed in accordance with local codes.

7. 

Do not over tighten connections.

8. 

Drain line ID must be at least 12mm.

9. 

Teflon tape should be used when installing he drain fitting into the control valve.

10. 

The drain line must be free of kinks.

11. 

A safety float with an air check is installed.

12. 

Insure all connections are tight.

13. 

To initiate regeneration, turn the twist the timer knob clockwise to the 2 hour position.

Note:  DO NOT use teflon tape when connecting the fitting kits to the control valve.

14.

There are two drain lines, one from the brine tank and one from the softener valve, these
lines  must  have  an  air  gap  of  at  least  40mm  or  twice  the  pipe  diameter  at  the  drain
entrance. The drain line from the brine tank is gravity fed and hence the drain is required
to be below the outlet elbow on the tank.

The  drain  line  from  the  softener  valve  is  under  pressure  during  regeneration  but  for
correct operation a maximum of 2.4m of 15NB pipe with no rises can be connected.

A manual Bypass should be installed.

Summary of Contents for SAS0922

Page 1: ...TING INSTRUCTIONS Model SAS0922 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commercial indus...

Page 2: ...imately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle Add...

Page 3: ...grams call C 3 Daily Water Usage in litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your...

Page 4: ...unit must be installed in accordance with local codes 7 Do not over tighten connections 8 Drain line ID must be at least 12mm 9 Teflon tape should be used when installing he drain fitting into the co...

Page 5: ...ensure the bypass valve is closed Run the nearest cold water tap for a least 15 minutes to ensure the resin bed is flushed BRINE TANK 1 Place at least 25kg of a coarse refined grade of salt Water Sof...

Page 6: ...SAS0922 Page 6 During regeneration raw hard water is bypassed to service so it is advisable to regenerate the unit when water is not needed...

Page 7: ...SAS0922 Page 7 Water Conditioning Control System Installation Operating and Maintenance Manual 541 030 VALVE...

Page 8: ...tube and up through the resin bed to drain This slow flow of water pushes the brine solution through the resin bed In brine draw concentrated salt brine is drawn from the brine tank and directed to fl...

Page 9: ...w o rings 1 16 529 244 Gasket Cross Over Port 1 17 541 244 Body Stem Assembly 1 18 185 024 1 O ring Small Seat Insert 1 19 541 204 Seal Insert 1 20 185 028 12 O ring Large Seat Insert 1 21 541 256 Mai...

Page 10: ...SAS0922 Page 10...

Page 11: ...set b Verify water usage matches system size and salt dosage c Replace safety float 4 Loss of resin a Faulty air check in storage tank b Leak at the distributor tube a Clean or replace air check b Ve...

Page 12: ...d that the outside edges of the main diaphragm are tucked into the valve body Rinse Adjustment Valve Replacement 1 Place the bypass valve into bypass position 2 Relieve the system pressure Remove the...

Page 13: ...ce a hand under the backcap and remove the backcap The check disc return spring will fall into your hand 5 Remove the check disc from the back of the body stem assembly 6 Inspect the rubber seal on th...

Page 14: ...or Cabinet Model Float Distance X SAS0715 100mm SAS0922 200mm SAS1029 260mm Adjustment of Softener Brine Valve 1 Lift float rod to full up position 2 Set float to distance shown Measure from the top o...

Reviews: