background image

SAS0922

Page 

7

Water Conditioning Control System

Installation, Operating and Maintenance Manual

541-030 VALVE

Summary of Contents for SAS0922

Page 1: ...TING INSTRUCTIONS Model SAS0922 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commercial indus...

Page 2: ...imately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle Add...

Page 3: ...grams call C 3 Daily Water Usage in litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your...

Page 4: ...unit must be installed in accordance with local codes 7 Do not over tighten connections 8 Drain line ID must be at least 12mm 9 Teflon tape should be used when installing he drain fitting into the co...

Page 5: ...ensure the bypass valve is closed Run the nearest cold water tap for a least 15 minutes to ensure the resin bed is flushed BRINE TANK 1 Place at least 25kg of a coarse refined grade of salt Water Sof...

Page 6: ...SAS0922 Page 6 During regeneration raw hard water is bypassed to service so it is advisable to regenerate the unit when water is not needed...

Page 7: ...SAS0922 Page 7 Water Conditioning Control System Installation Operating and Maintenance Manual 541 030 VALVE...

Page 8: ...tube and up through the resin bed to drain This slow flow of water pushes the brine solution through the resin bed In brine draw concentrated salt brine is drawn from the brine tank and directed to fl...

Page 9: ...w o rings 1 16 529 244 Gasket Cross Over Port 1 17 541 244 Body Stem Assembly 1 18 185 024 1 O ring Small Seat Insert 1 19 541 204 Seal Insert 1 20 185 028 12 O ring Large Seat Insert 1 21 541 256 Mai...

Page 10: ...SAS0922 Page 10...

Page 11: ...set b Verify water usage matches system size and salt dosage c Replace safety float 4 Loss of resin a Faulty air check in storage tank b Leak at the distributor tube a Clean or replace air check b Ve...

Page 12: ...d that the outside edges of the main diaphragm are tucked into the valve body Rinse Adjustment Valve Replacement 1 Place the bypass valve into bypass position 2 Relieve the system pressure Remove the...

Page 13: ...ce a hand under the backcap and remove the backcap The check disc return spring will fall into your hand 5 Remove the check disc from the back of the body stem assembly 6 Inspect the rubber seal on th...

Page 14: ...or Cabinet Model Float Distance X SAS0715 100mm SAS0922 200mm SAS1029 260mm Adjustment of Softener Brine Valve 1 Lift float rod to full up position 2 Set float to distance shown Measure from the top o...

Reviews: