background image

Summary of Contents for ASB200-908

Page 1: ...www ibase com tw IBASE Technology Inc ASB200 908 User Manual 2014 Nov Ver A1...

Page 2: ......

Page 3: ...ithout the express written permission of IBASE Technology INC IBASE Products and corporate names mentioned in this manual may or may not be registered trademarks or copyrights of their respective comp...

Page 4: ...1 3 1 Parts Description 11 1 4 Packing List 12 1 4 1 Optional Items 12 CHAPTER 2 MOTHERBOARD INTRODUCTION 13 2 1 Introduction 13 2 2 Board Dimensions 15 2 3 Setting the Jumpers 16 2 4 Jumper Location...

Page 5: ...gs on the chassis are for ventilation Do not block or cover these openings Make sure you leave plenty of space around the system for ventilation Never insert objects of any kind into the ventilation o...

Page 6: ...vice technician or your retailer The power cord or plug is damaged Liquid has been spilled into the system The system does not function properly even if you follow the operating instructions The syste...

Page 7: ...onal Inc AMD and ATI are registered trademarks of AMD Corporation Microsoft Windows is a registered trademark of Microsoft Corporation FINTEK is a registered trademark of FINTEK Electronics Corporatio...

Page 8: ...pports DVI I display output 2 x USB 3 0 2 x USB 2 0 1x CFAST expansion slot and 2 x Gigabit LAN giving a great selection for data communication in display applications The compact design 180 x 150 x 6...

Page 9: ...20GB 5400RPM Toshiba MQ01ABF032 HDD Front Panel I O 1 x power button 2 x USB2 0 1 x CFAST socket 1 x HDD LED Rear Panel I O 2 x Antenna reserved on real panel 1 x COM Ports 2 x DB9 for COM Port 1 x 12...

Page 10: ...Operating Temperature 0 C 45 C 14 F 113 F Storage Temperature 20 C 80 C 4 F 176 F Relative Humidity 5 90 45 C non condensing Vibration Operating 0 25Grms 5 500Hz Non operating 1Grms 5 500Hz Shock Ope...

Page 11: ...Copyright 2014 IBASE Technology Inc All Rights Reserved 9 IBASE Technology Inc 1 2 2 Dimensions...

Page 12: ...10 ASB200 908 User Manual 1 2 3 I O View Item Connector Item Connector 1 DVI I 5 1x RS232 2 12V 24V DC in 6 2x Gigabit LAN 3 2x RS232 for optional 7 2x USB3 0 4 1x RS232 422 485...

Page 13: ...e ASB200 908 Assembly 1 3 1 Parts Description Part No Description Part No Description 1 ASB200 908 Heatsink 2 DIP PCBA IB908 3 DIP PCBA ID112 4 DIP PCBA IBCFAST 5 BASE 6 ASB200 908_Front 7 2 5 HDD 8 C...

Page 14: ...cket MPCIE EXT V B1 Bracket RoHS Extend Half to Full size SC2MPCIEEXT0B1100P 3G Solution Description ZU 202 Wireless 3 75G UMTS HSPA ZU202 RoHS A008WIRELESS00520P ZU 200 Wireless 3 75G UMTS HSPA GPS M...

Page 15: ...s for DVI I LVDS displays 2 x SATA III connector 2x COM port connector 2 x Mini PCIe x1 slot w USB MSATA support 2x GbE RJ 45 connector 1x 12V to 24V DC IN power connector Product Name IB908F Form Fac...

Page 16: ...panel Serial ATA Ports Intel 4th Gen CoreTM i U series processor built in SATA controller 2 x SATA 3 0 6Gbps and 2 x mSATA via MiniPCIe slots w NXP CBTL02043A switching IC Audio Intel 4th Gen CoreTM...

Page 17: ...x1 for Audio DF11 1 x 4 pins box header x 1 for Speaker out 2x5 pins box header x 1 for COM2 2x5 pins headers x 1 for LPC Debug purpose only 5 pins box header x 1 for smart battery 4 pins box header x...

Page 18: ...8F to select various settings and features according to your needs and applications Contact your supplier if you have doubts about the best configuration for your needs The following lists the connect...

Page 19: ...ed 17 IBASE Technology Inc J3 Clear CMOS Contents J3 Setting Function Pin 1 2 Short Close d Normal Pin 2 3 Short Close d Clear CMOS J4 Clear ME Contents J4 Setting Function Pin 1 2 Short Close d Norma...

Page 20: ...scriptor Security Override Factory use only J7 Flash Descriptor Security Override Open Disabled Default Close Enabled J9 LVDS Panel Power Selection J9 Setting Panel Voltage Pin 1 2 Short Close d 3 3V...

Page 21: ...Copyright 2014 IBASE Technology Inc All Rights Reserved 19 IBASE Technology Inc Connector Locations on IB908F...

Page 22: ...tor CN7 DB9 Connector COM1 is a DB 9 connector Signal Name Pin Pin Signal Name DCD Data carrier detect 1 6 DSR Data set ready RXD Receive data 2 7 RTS Request to send TXD Transmit data 3 8 CTS Clear t...

Page 23: ...hnology Inc All Rights Reserved 21 IBASE Technology Inc Pin Signal Name RS 232 R2 422 RS 485 1 DCD TX DATA 2 RX TX DATA 3 TX RX NC 4 DTR RX NC 5 Ground Ground Ground 6 DSR NC NC 7 RTS NC NC 8 CTS NC N...

Page 24: ...2 SATA Connectors JP1 LCD Backlight Connector Pin Signal Name 1 12V 2 Backlight Enable 3 Brightness Control 4 Ground JP2 USB3 4 Connector Signal Name Pin Pin Signal Name Vcc 1 2 Ground D0 3 4 D1 D0 5...

Page 25: ...8 7 JD_LINEIN MIC R 10 9 MIC_L Ground 12 11 JD_MIC1 JP3 JP5 LVDS Connectors LVDS1 LVDS2 The LVDS connectors Hirose DF20G 20DP 1V on board consist of the first channel LVDS1 and second channel LVDS2 S...

Page 26: ...24 ASB200 908 User Manual JP4 SPI Flash Connector factory use only J5 Amplifier Connector Pin Signal Name 1 OUTL 2 OUTL 3 OUTR 4 OUTR J6 J8 DDR3L SO DIMM Sockets J7 Factory use only 9 10 1 2 1 4...

Page 27: ...Inc All Rights Reserved 25 IBASE Technology Inc JP6 SATA HDD Power Connectors Pin Signal Name 1 5V 2 Ground 3 Ground 4 12V JP7 Debug 80 Port Connector factory use only J11 MCU Flash Connector factory...

Page 28: ...26 ASB200 908 User Manual J12 Smart Battery Pin Signal Name 1 RST 2 ICHSWI 3 Ground 4 SMB_DATA 5 SMB_CLK J13 Board Input Power Connector Pin Signal Name 1 9V to 24V 2 GND 1 2 1 5...

Page 29: ...cators that provide light indication of the computer activities and switches to change the computer status J14 is an 8 pin header that provides interfaces for the following functions ATX Power ON Swit...

Page 30: ...ED Reset Switch Pins 7 and 8 The reset switch allows the user to reset the system without turning the main power switch off and then on again Orientation is not required when making a connection to th...

Page 31: ...RXD Receive data TXD Transmit data 3 4 Data terminal ready GND ground 5 6 DSR Data set ready RTS Request to send 7 8 CTS Clear to send RI Ring indicator 9 10 Not Used J19 Digital I O Connector Signal...

Page 32: ...30 ASB200 908 User Manual Pin Signal Name 1 Ground 2 12V 3 Rotation detection 4 Control 4 1...

Page 33: ...nter the Setup utility If you are a little bit late pressing the Del key POST Power On Self Test will continue with its test routines thus preventing you from invoking the Setup If you still wish to e...

Page 34: ...anguage Select Screen Select Item Enter Select Change Field F1 General Help F2 Previous Values F3 Optimized Default F4 Save ESC Exit Total memory 8176 MB DDR3 Memory Frequency 1600 Mhz System Date Tue...

Page 35: ...preference Aptio Setup Utility Main Advanced Chipset Boot Security Save Exit Select Screen Select Item Enter Select Change Field F1 General Help F2 Previous Values F3 Optimized Default F4 Save ESC Ex...

Page 36: ...efault F4 Save ESC Exit PCI Common Settings PCI Latency Timer 32 PCI Bus Clocks VGA Palette Snoop Disabled PERR Generation Disabled SERR Generation Disabled PCI Express Settings PCI Latency Timer Valu...

Page 37: ...Register Settings ASPM Support Disabled WARNING Enabling ASPM may cause PCI E devices to fail Extended Synch Disabled Link Training Retry 5 Link Training Timeout uS 100 Unpopulated Links Keep Link ON...

Page 38: ...ulated Links In order to save power software will disable unpopulated PCI Express links if this option set to Disable Link Restore PCIE Registers On non PCI Express aware OS s Pre Windows Vista some d...

Page 39: ...nter when the SUSPEND button is pressed Lock Legacy Resources Enabled or Disabled Lock of Legacy Resources S3 Video Repost Enable or disable S3 Video Repost Wake up event settings Aptio Setup Utility...

Page 40: ...ax CPU Speed 1700 MHz Min CPU Speed 800 MHz CPU Speed 800 MHz Processor Cores 2 Intel HT Technology Supported Intel VT x Technology Supported Intel SMX Technology Not Supported 64 bit Supported EIST S...

Page 41: ...IO 194 MSR Limit CPUID Maximum Disabled for Windows XP Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Intel Virtualization T...

Page 42: ...ller s Enabled SATA Mode Selection AHCI SATA Port0 Empty Software Preserve Hot Plug Unknown Disabled SATA Port1 Empty Software Preserve Hot Plug Unknown Disabled SATA Port2 Empty Software Preserve Hot...

Page 43: ...Shutdown Temperature Disabled ACPI Shutdown Temperature The default setting is Disabled iSmart Controller Aptio Setup Utility Main Advanced Chipset Boot Security Save Exit iSmart Controller Select Scr...

Page 44: ...Timer 0 AMT Configuration This configuration is supported only with IB902VF with iAMT function Options are Enabled and Disabled Note iAMT H W is always enabled This option just controls the BIOS exten...

Page 45: ...er time out 20 sec Device reset tine out 20 sec Device power up delay Auto Legacy USB Support Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE opt...

Page 46: ...anced Chipset Boot Security Save Exit NCT6102D Super IO Configuration Select Screen Select Item Enter Select Change Field F1 General Help F2 Previous Values F3 Optimized Default F4 Save ESC Exit NCT61...

Page 47: ...ture drops to a certain level it stops turning again Temperatures Voltages These fields are the parameters of the hardware monitoring function feature of the board The values are read only values as m...

Page 48: ...B1 PCI Express Configuration USB Configuration PCH Azalia Configuration PCH LAN Controller Enabled Wake on LAN Disabled SLP_S4 Assertion Width 1 2 Seconds PCH LAN Controller Enable or disable onboard...

Page 49: ...PCIe USB Glitch W A Disabled PCIE Root Function Swapping Subtractive Decode Disabled Disabled PCI Express Root Port 1 PCI Express Root Port 2 PCI Express Root Port 3 PCI Express Root Port 4 PCI E Por...

Page 50: ...s F3 Optimized Default F4 Save ESC Exit USB Precondition Disabled xHCI Mode Auto xHCI Idle L1 Enabled USB Ports Per Port Disable Control Disabled USB Precondition Precondition work on USB host control...

Page 51: ...l Help F2 Previous Values F3 Optimized Default F4 Save ESC Exit Azalia Auto Azalia PME Disabled Azalia Control Detection of the Azalia device Disabled Azalia will be unconditionally be disabled Enable...

Page 52: ...ersion 1 6 2 0 VT d Capability Supported VT d Enabled Graphics Configuration VT d Check to enable VT d function on MCH Graphics Configuration Aptio Setup Utility Main Advanced Chipset Boot Security Sa...

Page 53: ...E3 PCIE4 PCIE5 PCIE6PCIE7 Graphics device should be primary PCIE Internal Graphics Keep IGD enabled based on the setup options DVMT Pre Allocated Select DVMT 5 0 Pre Allocated Fixed graphics memory si...

Page 54: ...IGFX Boot Display Select the Video Device which will be activated during POST This has no effect if external graphics present Secondary boot display selection will appear based on your selection VGA...

Page 55: ...ou to configure the boot settings Aptio Setup Utility Main Advanced Chipset Boot Security Save Exit Boot Configuration Select Screen Select Item Enter Select Change Field F1 General Help F2 Previous V...

Page 56: ...Enables Disables Quiet Boot option Fast Boot Enables Disables boot with initialization of a minimal set of devices required to launch active boot option Has no effect for BBS boot options Boot Option...

Page 57: ...aunch Launch Storage OpROM policy Legacy only Launch Video OpROM policy Legacy only Other PCI device ROM priority Legacy OpROM Launch CSM This option controls if CSM will be launched Boot option filte...

Page 58: ...ous Values F3 Optimized Default F4 Save ESC Exit If ONLY the Administrator s password is set then this only limit access to Setup and is only asked for when entering Setup If ONLY the User s password...

Page 59: ...nges and Exit Save Changes and Reset Discard Changes and Reset Save Options Save Changes Discard Changes Restore Defaults Save as User Defaults Restore User Defaults Save Changes and Exit Exit system...

Page 60: ...es done so far to any of the setup options Restore Defaults Restore Load Defaults values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defa...

Page 61: ...alling your Windows operating system you must install first the Intel Chipset Software Installation Utility before proceeding with the drivers installation 4 1 Intel Chipset Software Installation Util...

Page 62: ...00 908 User Manual 3 When the Welcome screen to the Intel Chipset Device Software appears click Next to continue 4 Click Yes to accept the software license agreement and proceed with the installation...

Page 63: ...Inc All Rights Reserved 61 IBASE Technology Inc 5 On the Readme File Information screen click Next to continue the installation 6 The Setup process is now complete Click Finish to restart the computer...

Page 64: ...62 ASB200 908 User Manual 4 2 VGA Drivers Installation 1 Insert the DVD that comes with the board Click Intel and then Intel R 8 Series Chipset Drivers 2 Click Intel R Core TM i3 i5 i7 Graphics Driver...

Page 65: ...2014 IBASE Technology Inc All Rights Reserved 63 IBASE Technology Inc 3 When the Welcome screen appears click Next to continue 4 Click Yes to to agree with the license agreement and continue the inst...

Page 66: ...64 ASB200 908 User Manual 5 On the screen shown below click Install to continue 6 Setup complete Click Finish to restart the computer and for changes to take effect...

Page 67: ...Inc All Rights Reserved 65 IBASE Technology Inc 4 3 Realtek HD Audio Driver Installation 1 Insert the DVD that comes with the board Click Intel and then Intel R 8 Series Chipset Drivers 2 Click Realt...

Page 68: ...al 3 On the Welcome to the InstallShield Wizard screen click Yes to proceed with and complete the installation process 4 The InstallShield Wizard Complete Click Finish to restart the computer and for...

Page 69: ...echnology Inc All Rights Reserved 67 IBASE Technology Inc 4 4 LAN Driver Installation 1 Insert the DVD that comes with the board Click Intel and then Intel R 8 Series Chipset Drivers 2 Click Intel R P...

Page 70: ...68 ASB200 908 User Manual 3 Click Install Drivers and Software 4 When the Welcome screen appears click Next...

Page 71: ...BASE Technology Inc All Rights Reserved 69 IBASE Technology Inc 5 Click Next to to agree with the license agreement 6 Click the checkbox for Drivers in the Setup Options screen to select it and click...

Page 72: ...70 ASB200 908 User Manual 7 The wizard is ready to begin installation Click Install to begin the installation 8 When InstallShield Wizard is complete click Finish...

Page 73: ...echnology Inc All Rights Reserved 71 IBASE Technology Inc Intel Management Engine Interface 1 Insert the DVD that comes with the board Click Intel and then Intel R 8 Series Chipset Drivers and then In...

Page 74: ...er Manual 2 When the Welcome screen to the InstallShield Wizard for Intel Management Engine Components click the checkbox for Install Intel Control Center click Next 3 Click Yes to to agree with the l...

Page 75: ...yright 2014 IBASE Technology Inc All Rights Reserved 73 IBASE Technology Inc 4 When the Setup Progress screen appears click Next Then click Finish when the setup progress has been successfully install...

Page 76: ...74 ASB200 908 User Manual Intel USB 3 0 Drivers 1 Insert the DVD that comes with the board Click Intel and then Intel R 8 Series Chipset Drivers 2 Click Intel R USB 3 0 Drivers...

Page 77: ...Rights Reserved 75 IBASE Technology Inc 3 When the Welcome screen to the InstallShield Wizard for Intel USB 3 0 eXtensible Host Controller Driver click Next 4 Click Yes to to agree with the license a...

Page 78: ...al 5 On the Readme File Information screen click Next to continue the installation of the Intel USB 3 0 eXtensible Host Controller Driver 6 Setup complete Click Finish to restart the computer and for...

Page 79: ...M3 length 6mm screws to secure the system on wall Four M3 length 6mm screws Four M3 length 4 4mm for VESA mounting are recommended to secure the system on wall Fasteners are not included with the unit...

Page 80: ...plicable building and electric codes When mounting ensure that you have enough room for power and signal cable routing And have good ventilation for power adapter The method of mounting must be able t...

Page 81: ...acceptable Mounting to a solid concrete or brick wall Mounts on a flat smooth surface Selecting the Location Plan the mounting location thoroughly Locations such as walkway areas hallways and crowded...