- 10 -
b.
Compulsory Defrosting: When heat pump is heating, press
and
together for 5 seconds to start compulsory defrosting, and
will be
flashing. After defrosting,
will stop flashing.
(Note: Compulsory defrosting intervals should be more than 30 minutes
and the compressor should run for more than 10 minutes.)
5.
Temperature display conversion between
℃
and
℉
:
Press "
"
and "
" together for 5 seconds to switch
between
℃
and
℉
.
6.
Wi-Fi setting: Please kindly check the last page.
7.
Advanced application
7.1. Parameter Checking
a.
Press
and
together for 5 seconds to enter “Parameter
Checking” status, the parameter code“P0” and the parameter value “0”
will display on the screen, such as “P0 0”, which means water pump
running way is continuous.
b.
In“Parameter Checking” status, press
or
to check the
parameters.
7.2. Parameter Modification
In“Parameter Checking” status, press
to enter the “Parameter
Modification” mode, press
or
to change the values, then press
to confirm and quit “Parameter Modification” mode, press
to
quit “Parameter Checking” status.