3)
WARNING: Before obtaining access to terminals, all supply circuits must
be disconnected.
4)
5-6 terminal: Customer remote control switch connector,
to reach automation control through 2-wire dry contact connection,
and only control the unit On/Off.
3.
Options for protecting devices and cable specification
※
Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire
diameter must be increased. The signal cable can be extended to 50m at
most.
4.
Installation and Requirements
The swimming pool heat pump must be installed by a pool professional. End
users are not qualified to install by themselves, otherwise the heat pump
might be damaged and risky for user’s safety.
Notes:
1)
The inlet and outlet water unions can’t bear the weight of soft pipes. The
heat pump must be connected with hard pipes!
MODEL
BCP30K
BCP40K
BCP50K
BCP65K
BCP90K
BCP110K
BCP140K
Breaker
Rated Current (A)
13.0
13.0
15.5
20.0
26.0
40.0
44.0
Rated Residual
Action Current
(mA)
30
30
30
30
30
30
30
Max input current (A)
10.8
10.8
12.8
16.8
21.5
32.5
40.0
Fuse (A)
13.0
13.0
15.5
20.0
26.0
40.0
44.0
Power Cord (AWG)
3×13
3×13
3×13
3×11
3×10
3×8
3×8
Signal cable (AWG)
3x20
3x20
3x20
3x20
3x20
3x20
3x20
Jumper is installed by default, if loosen or disconnection
“OFF” will display.