- 8 -
PUTTING INTO OPERATION
Check that the voltage on the identification plate is the same
as that of the network.
THE ELECTRICAL SUPPLY LINE
TO WHICH THE REFRIGERATOR WILL HAVE TO
BE CONNECTED IS TO BE PROTECTED BY A VERY
SENSITIVE DIFFERENTIAL SWITCH
(Rc=16A,Dc=30mA); IT IS ALSO TO BE LINKED TO
THE GENERAL EARTHING PLANT.
The manufacturer disclaims all responsability for any damage
to people or
things due to incorrect observance of this rule.
Earthing is necessary and compulsory by law. Absolutely
never use reduction units, patch cords, adapters or multi-
ple socket outlets to connect the counter. DIRECTLY
connect the equipment to the mains.
After plugging, make run the unit for about 2 hours with the
lights off, then load the product: don' t place it over the max.
load level because the temperature for good preservation is
insufficient.
For a good preservation of the cabinet's body
a periodical cleaning is necessary
.
EXTERNAL BODY
: When necessary, the external body should be cleaned with a cloth and a
neutral
soap
and water solution.
STAINLESS STEEL SURFACES
: wash with warm water and mild detergent, rinse well and dry with
soft cloth.
Avoid scouring pads etc. which will spoil the finish of the stainless steel.
SURFACES IN PLASTIC MATERIAL
: wash with warm water and mild detergent, rinse well and dry
with soft cloth;
under no circumstances should alcohol, methylated spirits or solvents be used.
GLASS SURFACES
: only use products specifically designed for glass cleaning;
it is not advisable to
use ordinary water which can leave a film of calcium on the surface of the glass.
PERIODICAL MAINTENANCE
Any further adjustments on the refrigerator necessarily require the electric plug to be removed.
Check periodically the supply cable in order to detect any damage. If the power supply cable is damaged,
don't use the equipment and don't try to repair it: to prevent any risk, it must be replaced by the manufacturer,
by a member of the after-sales service staff, or anyway by a person having similar qualifications. In any case,
none of the protective elements (the grill, the carter) must be removed by non qualified staff. Absolutely
avoid using the refrigerator without such protection.
The replacement of neon tubes must be carried out only by an Authorized Service Center.
(SKILLED PERSONNEL ONLY)
At least once every 12 months remove from the condenser
unit the impurity (dust and deposit) which remain among
the fins of the condenser, obstructing a good circulation
of the air
.
A dirty condenser reduces the performance of
the equipment, increasing the energy consumption.
Cleaning should be carried out with a soft brush or
preferably with a vacuum cleaner.
Summary of Contents for Eis 45
Page 27: ...27 EIS 30 40 33 43 GROSS VOL 397 dm NET VOL 295 dm...
Page 28: ...28 EIS 34 45 GROSS VOL 397 dm NET VOL 267 dm...
Page 29: ...29 EIS 55 GROSS VOL 482 dm NET VOL 335 dm...
Page 30: ...30 STAR 30 40 33 43 GROSS VOL 375 dm NET VOL 267 dm...
Page 31: ...31 STAR 34 45 GROSS VOL 397 dm NET VOL 267 dm...
Page 32: ...32 STAR 55 GROSS VOL 482 dm NET VOL 335 dm...
Page 33: ...33 STAR 43 LUX GROSS VOL 390 dm NET VOL 275 dm...
Page 34: ...34 VFP 33 30 NET VOL 230 dm...