MAN-043/B
17
2.8.8
FIX THE GROUND CABLE TO THE
ELECTRIC STARTER BY MEANS OF THE
M6x12 SCREW (ALREADY ON THE ENGINE
SEE FIG. 21).
TORQUE AT 8 ÷ 10 Nm (70 ÷90 in-lb)
ATTENTION:
THIS OPERATION IS EXTREMELY
IMPORTANT AS AN UNCERTAIN
GROUNDING COULD DAMAGE THE
POWER-PACK BEYOND REPAIR.
5 mm ALLEN
2.8.9
FIX THE EYELET TERMINAL (Ø
6.5mm),
OF THE SECOND GROUND CABLE IN THE
HARNESS (CLOSE TO THE COIL CABLE) TO
THE H.T. COIL. BY MEANS OF THE M6 NUT
FIXING THE COIL (SEE FIG. 22).
TORQUE AT 8 ÷ 10 Nm (70 ÷90 in-lb)
ATTENTION:
THIS OPERATION IS EXTREMELY
IMPORTANT AS AN UNCERTAIN
GROUNDING COULD DAMAGE THE POWER
PACK BEYOND REPAIR.
10mm BOX WRENCH
2.8.10
CONNECT THE H.T. COIL CABLE TO
THE HARNESS TERMINAL (SEE FIG. 23).
ATTENTION:
FASTEN THE COIL CABLE WITH A PLASTIC
CLAMP TO AVOID THAT EVENTUAL
VIBRATIONS MIGHT DISCONNECT THE
TERMINALS (SEE FIG. 24).
Fig.21
Fig.22
Fig.24
Fig.23