2. Installation
49
2.3 How to Install
This chapter explains how to install the actuator on your mechanical system.
2.3.1 Installation
Follow the information below when installing the actuator, as a rule.
Do pay attention to these items (except with custom-order models).
{
: Possible
ڹ
: Daily inspection is required
u
: Not possible
Model
Horizontal
installation
Vertical installation
Sideways
installation
Ceiling Mount
installation
SA4C, SA4R,
SA6C, SA6R,
SA7C, SA7R
{
{
ڹ
ڹ
Installation Orientation
Horizontal
Vertical
Sideways
Ceiling mount
Caution: 1. When the unit is installed vertically oriented, Motor straight type is attempt to put
the motor up unless there is a special reason. Putting the motor on the lower side
would not cause a problem in an ordinary operation. However, it may rarely
cause a problem, when it is not operated for a long period, depending on the
surrounding environment (especially high temperature), caused by the grease
being separated and the base oil flowing into the motor unit.
2. Can be installed sideways or ceiling mount, but the actuators must be checked
daily. If the actuator is installed sideways or ceiling mount, the stainless steel
sheet may be slacked or displaced. If the actuator is used continuously while the
stainless steel sheet is slacked or displaced, the stainless steel sheet may break
or other problems may occur. Check the actuator daily and if the stainless steel
sheet is found slacked or displaced, make installation adjustment of the stainless
steel sheet. [Refer to 4.7 Procedure for Stainless Steel Sheet Replacement and
Adjustment.]