![IAI PSA-24 Instruction Manual Download Page 76](http://html1.mh-extra.com/html/iai/psa-24/psa-24_instruction-manual_604103076.webp)
11.1 Relation of Actuator and Power Supply Current
11-7
11.
A
pp
end
ix
Table 1-7. Relation of Actuator and Power Supply Current (Controller integrated actuator)
Actuator
type
Motor power
capacity
Power supply current [A]
(Note 1)
ELECYLINDER
EC-PR4,
EC-GS4,
EC-GD4,
EC-TC4,
EC-TW4
Maximum
2.0
Other than the
above
Energy-saving
setting enabled
Maximum
2.2
Energy-saving
setting disabled
Rated
3.5
Maximum
4.2
ERC3
High-output setting
disabled
Maximum
2.2
High-output setting
enabled
Rated
3.5
Maximum
4.2
RCP6S
35P,
42P,
56P
High-output setting
disabled
Maximum
2.0
High-output setting
enabled
Rated
3.5
Maximum
4.5
56SP, 60P
Maximum
6.0
Note 1 Power supply current includes control power supply current.
(Note) 0.3A higher for the fieldbus specification.
The calculation method for RCP6S gateway system power capacity is explained in the RCP6S
fieldbus communication instruction manual.
Refer to "1.3 Calculation of Number of Connectable Axes and Power Capacity".
Summary of Contents for PSA-24
Page 6: ......
Page 17: ...Part Names Intro 11 Part Names PSA 24 204W without fan PSA 24L 330W with fan ...
Page 30: ...1 2 General Specifications 1 7 1 Specifications ...
Page 36: ...2 2 Heat Dissipation and Mounting 2 5 2 Installation ...
Page 55: ...Before Considering Failure 6 1 Before Considering Failure 6 1 Power supply unit Chapter 6 ...
Page 59: ...External Dimensions 8 1 External Dimensions 8 1 Power supply unit Chapter 8 ...
Page 63: ...Life 9 1 Consumable Parts 9 1 Power supply unit Chapter 9 ...
Page 68: ...10 3 10 Warranty ...
Page 83: ......