11.1 Relation of Actuator and Power Supply Current
11-6
11.
A
pp
end
ix
Table 1-6. Relation of Actuator and Power Supply Current (MSEP)
Controller
type
Actuator
type
Motor power
capacity
Power supply current [A]
(Note 1)
MSEP
(Note 2)
RCL
2W
Rated
0.8
Maximum
4.6
5W
Rated
1.0
Maximum
6.4
10W
Rated
1.3
Maximum
6.4
RCA
RCA2
10W
Rated
1.3
Power saving
maximum
2.5
Maximum
4.4
20W
Rated
1.3
Power saving
maximum
2.5
Maximum
4.4
20W
(Model notation 20S)
Rated
1.7
Power saving
maximum
3.4
Maximum
5.1
30W
Rated
1.3
Power saving
maximum
2.2
Maximum
4.0
RCD
3W
Rated
0.7
Maximum
1.5
RCP2
RCP3
20P, 28P,
28SP, 35P,
42P, 56P
Maximum
2.0
RCP4
RCP5
28P, 35P,
42P, 42SP,
56P
High-output
setting disabled
Maximum
2.0
High-output
setting enabled
Rated
3.5
Maximum
4.2
Note 1 The power supply current is for 1-axis and does not include the control power supply current.
Note 2 MSEP control power supply current is 1.0A. (Brake release power capacity is not included)
(Note) 0.3A higher for the fieldbus specification.
To calculate the power supply current, refer to "1.3 Power Supply Capacity Calculation" in the MSEP
instruction manual.
Summary of Contents for PSA-24
Page 6: ......
Page 17: ...Part Names Intro 11 Part Names PSA 24 204W without fan PSA 24L 330W with fan ...
Page 30: ...1 2 General Specifications 1 7 1 Specifications ...
Page 36: ...2 2 Heat Dissipation and Mounting 2 5 2 Installation ...
Page 55: ...Before Considering Failure 6 1 Before Considering Failure 6 1 Power supply unit Chapter 6 ...
Page 59: ...External Dimensions 8 1 External Dimensions 8 1 Power supply unit Chapter 8 ...
Page 63: ...Life 9 1 Consumable Parts 9 1 Power supply unit Chapter 9 ...
Page 68: ...10 3 10 Warranty ...
Page 83: ......