5.1 Preventive Maintenance Function
5-3
5.
P
rev
ent
ive
/ P
re
dic
tiv
e M
ai
nt
ena
nc
e
● Switch overload error threshold
The rated current changes depending on whether a fan is connected or not, so the internal
overload error threshold is also switched after detecting the fan connection. If fan abnormal
rotation speed is detected, there is a possibility of significant decrease in life or failure of
continuous operation, so the threshold value for overload error will be forcibly switched to the
threshold for continuous rated output 204W (without fan).
● Fan ON/OFF control by internal temperature
When the ambient temperature is low or when the environment has capacity for more load, the
internal temperature sensor
may turn the fan ON/OFF in order to extend its life. The ON/OFF
control specifications of the fan using an internal temperature sensor are as follows.
Item
Specifications
ON
Continues for 10 seconds at 60°C or higher
OFF
Continues for 10 seconds at 50°C or below
Summary of Contents for PSA-24
Page 6: ......
Page 17: ...Part Names Intro 11 Part Names PSA 24 204W without fan PSA 24L 330W with fan ...
Page 30: ...1 2 General Specifications 1 7 1 Specifications ...
Page 36: ...2 2 Heat Dissipation and Mounting 2 5 2 Installation ...
Page 55: ...Before Considering Failure 6 1 Before Considering Failure 6 1 Power supply unit Chapter 6 ...
Page 59: ...External Dimensions 8 1 External Dimensions 8 1 Power supply unit Chapter 8 ...
Page 63: ...Life 9 1 Consumable Parts 9 1 Power supply unit Chapter 9 ...
Page 68: ...10 3 10 Warranty ...
Page 83: ......